background image

Summary of Contents for SL Strip 400 RGBW Led Luminaire

Page 1: ......

Page 2: ...it dans ce manuel est pour information seulement et est sujet à changements sans préavis La compagnie Showline n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s il vous plait contacter le bureau de Showline le plus proche Note Information contained in t...

Page 3: ...ent should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Do not use this equipment for other than intended use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker...

Page 4: ... Power 6 Connecting SL STRIP 400 RGBW LED Luminaires to AC Power 7 Connecting to the DMX512 Network 8 Mounting Luminaire 9 OPERATION AND PROGRAMMING LCD Display and Menu System 11 LCD Display and Menu System Operation 11 Quick Selection Buttons 13 Edit a Preset Button 13 Edit a Chase Button 13 DMX Address Button 13 Dimming Curve Selection 14 Master Slave Operational Mode 15 DMX CONTROL 16 Bit Mode...

Page 5: ...l for future reference Additional product information and descriptions may be found on the product specification sheet Note The SL STRIP 400 RGBW LED Luminaire is universal voltage 100 to 240 VAC auto ranging 2 Included Items Each SL STRIP 400 RGBW LED Luminaire includes the following items SL STRIP 400 RGBW LED Luminaire Installation and User s Manual this document 3 SL STRIP 400 RGBW LED Luminai...

Page 6: ...mponents Major Luminaire Components Figure 1 SL STRIP 400 RGBW LED Luminaire Components Note Mounts can be removed and reversed See Mounting Luminaire on page 9 for more information Side of Unit Bottom of Unit DMX512 AC Input LCD Display Menu System Luminaire Mount Safety Cable Anchor Point RDM Input Top of Unit DMX512 AC Output RDM Output Luminaire Mount High Intensity RGBW LED Array x36 ...

Page 7: ...Installation User s Manual ...

Page 8: ... For wiring of AC input connector refer to Connecting SL STRIP 400 RGBW LED Luminaires to AC Power on page 7 2 Connecting Power Units can be powered in one of two ways Direct connection to a AC power source using an AC input cable For wiring of AC input connector refer to Con necting SL STRIP 400 RGBW LED Luminaires to AC Power on page 7 Connection from the AC output of another SL STRIP 400 RGBW L...

Page 9: ... 400 RGBW LED Luminaire is straight forward A total of 3 wires conductors is supplied from the unit The following wiring scheme is used Table 2 SL STRIP 400 RGBW LED Luminaire IP65 Rated Models AC Input Connections Figure 3 SL STRIP 400 RGBW LED Luminaire AC Input Output Connections CAUTION In the event the AC input cable of this luminaire is damaged it must be replaced by the user with an approve...

Page 10: ...LED Luminaire or DMX512 device to be controlled Figure 4 SL STRIP 400 RGBW LED Luminaire DMX512 Input Output Connections Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 For SL STRIP 400 RGBW LED Luminaire DMX Mapping refer to DMX CONTROL on page 16 Figure 5 SL STRIP 400 RGBW LED Luminaire DMX512 Connections Bottom of Unit DMX512 RDM Inp...

Page 11: ...in Major Luminaire Components on page 4 The two mounts are easily removed and reversed as required as illustrated in Figure 6 These mounts are designed to accept a variety of mounting hooks clamps etc for hanging applications or can be set on the mounts for floor applications Refer to Figure 7 for additional information Figure 6 Mount Removal and Installation OR OR Mount Screws x2 Mount Mount Moun...

Page 12: ...c are sold separately or by others For available mounting accessories refer to SL STRIP 400 RGBW LED Luminaire Accessories on page 3 Figure 7 Mounting Luminaire Hanging Applications Hooks Clamps sold separately Mount SAFETY CABLE Is sold separately and recommended for all hanging installation and may be required by national and local codes Use safety cable anchor point for this fixture Mounting ho...

Page 13: ......

Page 14: ......

Page 15: ...l chases Built In and User Chases Note For Built In Chases only the Speed and Fade parameters may be changed and saved For User Chases Chase Number Total Steps Speed and Fade Parameters may be changed and saved Step 3 Once at desired chase use UP and DOWN arrows to access highlight chase parameters Once in desired parameter use LEFT and RIGHT arrow buttons to adjust parameter value as desired Step...

Page 16: ...o select one of four dimming curves Linear Curve PL_Curve S_Curve Square Curve Figure 10 SL STRIP 400 RGBW LED Luminaire Dimmer Curves PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries DMX Value Lumen Output 0 Linear Curve DMX Value Lumen Output 0 S_Curve DMX Value Lumen Output 0 Square Curve DMX Value Lumen Output 0 PL_Curve ...

Page 17: ...er Mode through the unit s menu system Step 2 Set all other connected units to Slave Mode Step 3 The master unit can be controlled via DMX512 RDM or through standalone operation self contained network utilizing on board effects The slave units will mimic the master unit s operation in all cases Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on p...

Page 18: ...Installation User s Manual ...

Page 19: ...3 ...

Page 20: ...4 5 6 7 8 ...

Page 21: ...2 ...

Page 22: ...2 3 4 ...

Page 23: ...5 6 Installation User s Manual ...

Page 24: ...Installation User s Manual ...

Page 25: ...5 8 30 6 12 31 6 2 32 6 4 13 33 6 6 34 6 8 35 7 0 14 36 7 2 37 7 4 15 38 7 6 39 7 8 40 8 16 41 8 2 42 8 4 17 43 8 6 44 8 8 45 9 18 46 9 2 47 9 4 19 48 9 6 49 9 8 50 10 20 51 10 2 52 10 4 53 10 6 21 54 10 8 55 11 22 56 11 2 57 11 4 58 11 6 23 59 11 8 60 12 24 61 12 2 62 12 4 63 12 6 25 64 12 8 65 13 26 66 13 2 67 13 4 68 13 6 Table 6 SL STRIP 400 RGBW LED Luminaire Timing Channel Detail Value DMX S...

Page 26: ... 4 83 16 6 33 84 16 8 85 17 86 17 2 34 87 17 4 88 17 6 35 89 17 8 90 18 91 18 2 36 92 18 4 93 18 6 37 94 18 8 95 19 96 19 2 38 97 19 4 98 19 6 39 99 19 8 100 20 101 21 40 102 22 103 23 104 24 41 105 25 106 26 42 107 27 108 28 109 29 43 110 30 111 31 44 112 32 113 33 114 34 45 115 35 116 36 46 117 37 118 38 119 39 Table 6 SL STRIP 400 RGBW LED Luminaire Timing Channel Detail Value DMX Seconds unles...

Page 27: ...50 131 51 132 52 52 133 53 134 54 53 135 55 136 56 137 57 54 138 58 139 59 55 140 60 141 61 142 62 56 143 63 144 64 57 145 65 146 66 147 67 58 148 68 149 69 59 150 70 151 71 152 72 60 153 73 154 74 155 75 61 156 76 157 77 62 158 78 159 79 160 80 63 161 81 162 82 64 163 83 164 84 165 85 65 166 86 167 87 66 168 88 169 89 170 90 Table 6 SL STRIP 400 RGBW LED Luminaire Timing Channel Detail Value DMX ...

Page 28: ...86 106 187 107 188 108 74 189 109 190 110 75 191 111 192 112 193 113 76 194 114 195 115 77 196 116 197 117 198 118 78 199 119 200 100 79 201 121 202 122 203 123 80 204 124 205 125 81 206 126 207 127 208 128 82 209 129 210 130 211 131 83 212 132 213 133 84 214 134 215 135 216 136 85 217 137 218 138 86 219 139 220 140 221 141 Table 6 SL STRIP 400 RGBW LED Luminaire Timing Channel Detail Value DMX Se...

Page 29: ... Parameters IDs on page 28 Table 8 SL STRIP 400 RGBW LED Luminaire RDM UID on page 28 Table 9 SL STRIP 400 RGBW LED Luminaire RDM Parameters IDs on page 28 Table 10 SL STRIP 400 RGBW LED Luminaire RDM Manufacturer Status IDs on page 30 87 222 142 223 143 88 224 144 225 145 226 146 89 227 147 228 148 229 149 90 230 150 231 151 91 232 152 233 153 234 154 92 235 155 236 156 93 237 157 238 158 239 159...

Page 30: ...ork Management DISC_UNIQUE_BRANCH 0x0001 DISC_MUTE 0x0002 DISC_UN_MUTE 0x0003 PROXIED_DEVICES 0x0010 PROXIED_DEVICES_COUNT 0x0011 COMMS_STATUS 0x0015 Category Status Collection QUEUED_MESSAGE 0x0020 STATUS_MESSAGES 0x0030 STATUS_ID_DESCRIPTION 0x0031 CLEAR_STATUS_ID 0x0032 SUB_DEVICE_STATUS_REPORT_THRESHOLD 0x0033 Category RDM Information SUPPORTED_PARAMETERS 0x0050 Support required only if suppor...

Page 31: ...ngs 0x03xx FUTURE USE Category Power Lamp Settings 0x04xx DEVICE_HOURS 0x0400 LAMP_HOURS 0x0401 LAMP_STRIKES 0x0402 LAMP_STATE 0x0403 LAMP_ON_MODE 0x0404 DEVICE_POWER_CYCLES 0x0405 Category Display Settings 0x05xx DISPLAY_INVERT 0x0500 DISPLAY_LEVEL 0x0501 Category Configuration 0x06xx PAN_INVERT 0x0600 TILT_INVERT 0x0601 PAN_TILT_SWAP 0x0602 REAL_TIME_CLOCK 0x0603 Category Control 0x10xx IDENTIFY...

Page 32: ... is 0x8000 0xffdf See ANSI E1 20 2010 Standard Table A 3 8A00H U8 1 None None 0 100 100 DIMMER 8A04H U8 1 None None 0 100 100 Dimmer RED 8A05H U8 1 None None 0 100 100 Dimmer GREEN 8A06H U8 1 None None 0 100 100 Dimmer BLUE 8A07H U8 1 None None 0 100 100 Dimmer WHITE 8AB2H U8 1 None None 1 18 1 Chase 8AB0H U8 1 None None 0 43 0 Color Filter 8AB1H U8 1 None None 0 31 0 Preset 8A92H U8 1 None None 0...

Page 33: ...naire plastic optics with anti reflection coatings If the lens is still dirty after using isopropyl alcohol for instance if fingerprints or oil is just redistributed and not cleaned off the optic then a mild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based...

Page 34: ...Control Protocols DMX512 1990 DMX512A RDM On Board Menu Ambient Temperature 20 to 40 Degrees C 4 to 104 Degrees F Humidity 5 95 Non condensing Cooling Natural Convection Weight 15 0 lbs 6 8 kg Luminaire only no accessories Housing Die Cast Aluminium with Powder Coating Compliance CE Marked International models IP Rating IP65 Note Common model specifications shown For specific model specifications ...

Page 35: ...SL STRIP 400 RGBW LED Luminaire Dimensions 33 SL STRIP 400 RGBW LED Luminaires Installation User s Manual Sh wline Notes ...

Page 36: ......

Reviews: