Troubleshooting 

This troubleshooting guide is meant to help solve simple problems.  

If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 

operates properly, do not carry out following steps. 

 

No Light 

If the light effect does not operate properly, refer servicing to a technician. 

Suspect three potential problem areas as: the power supply, the lamp, the fuse. 

01)

 

Power supply. Check that the unit is plugged into an appropriate power supply. 

02)

 

The lamp. See page 11 for replacing the lamp. 

03)

 

The fuse. Replace the fuse. See page 11 for replacing the fuse. 

04)

 

If all of the above appears to be O.K., plug the unit in again.  

05)

 

If you are unable to determine the cause of the problem, do not open the Studio Beam, as this may 

damage the unit and the warranty will become void. 

06)

 

Return the device to your Showtec dealer. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem 

Probable cause(s) 

Solution 

 

One or more 

fixtures do not 

function at all 

No power to the fixture 

•  Check if power is switched on and 

cables are plugged in 

Primary fuse blown 

•  Replace the fuse. 

 

 

 

No light or lamp 

cuts out 

intermittently 

Fixture is too hot 

•  Allow the fixture to cool down 

•  Make sure air vents in control 

panel and the front lens are not 

blocked 

•  Turn up the air conditioning 

 

Lamp is damaged 

•  Replace the lamp 

•  Disconnect the fixture and return it 

to your dealer 

The power supply settings do not 

match local AC voltage and 

frequency 

•  Disconnect fixture. Check settings 

and correct if necessary 

 

  

 

 

12 

   

 

Summary of Contents for 30690

Page 1: ...Studio Beam CDM HCI 150 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30690 MANUAL ENGLISH ...

Page 2: ...n of the device 7 Overview 7 Backside 8 Installation 8 Set Up and Operation 8 Installing the lamp 9 Color frame retaining clip 9 Available lenses 10 Changing the lens 10 Removing the lens 10 Maintenance 11 Changing the lamp 11 Replacing the Fuse 11 Cleaning VNSP NSP MFL and WFL glass lenses 11 Troubleshooting 12 No Light 12 Product Specifications 13 Dimensions 14 1 ...

Page 3: ... shipment includes Showtec Studio Beam CDM HCI 150 with power cable 1 m Filter frame User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before the initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and d...

Page 4: ...wer from the mains when device is not used or before cleaning or when replacing lamp Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Ch...

Page 5: ...burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Studio Beam is lowered from the ceiling or high joists professional trussin...

Page 6: ...nect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make sure that the device is always properly connected to the earth Improper installation can cause serious injuries and or damage of...

Page 7: ... number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of ...

Page 8: ...tardant plastic Connections Schuko power cable 1 m Lenses VNSP NSP MFL WFL Color Black Fuse T3 15AL 250V Dimensions 285 x 270 x 380 mm LxWxH Weight 6 6 kg Optional accessories 30696 Filter frame for Studio Beam 30698 Barndoor for Studio Beam 80964 Powerstar HCI CDM G12 Osram 150W 80965 Powerstar HCI CDM G12 Osram 150W 80974 Discharge Bulb Philips G12 80975 Discharge Bulb Philips G12 Overview Fig 0...

Page 9: ...Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power suppl...

Page 10: ...d for Damages caused by non observance are not subject to warranty 01 Disconnect the Studio Beam from power before installing the lamp 02 Loosen the knurled bolt and remove the lamp housing 03 Remove the lamp from the box and hold it by the base Read lamp instructions Do not touch the lamp bulb glass Oil on hands shortens the lamp s lifespan If you touch the bulb glass wipe it off with a clean lin...

Page 11: ...its base behind the tabs on the bottom of the rotation ring 05 Gently push the lens until it is positioned properly Fig 06 Fig 07 Fig 08 Removing the lens The CDM lenses become hot while operating the device Let the device cool down before removing a lens 01 Place the fixture on a flat surface 02 Position the lens rotating ring in the way that its spring clip is situated at the top of the unit 03 ...

Page 12: ...sh and vacuum cleaner Make sure connections are thoroughly dry before supplying electric power Changing the lamp 01 Disconnect mains power supply Loosen the knurled bolt on the back of the device 02 Remove the rear cover 03 Follow directions for installing the lamp page 9 Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse...

Page 13: ... above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Studio Beam as this may damage the unit and the warranty will become void 06 Return the device to your Showtec dealer Problem Probable cause s Solution One or more fixtures do not function at all No power to the fixture Check if power is switched on and cables are plugged in P...

Page 14: ... T 150W 942 discharge lamp included Light output 14000 lumen 4200K Lenses VNSP NSP MFL WFL Housing Metal flame retardant plastic Color Black Connections Dedicated Schuko Max ambient temperature ta 25 C Max housing temperature tB 70 C Minimum distance Minimum distance from flammable surfaces 0 5 m Minimum distance to lighted object 1 m Design and product specifications are subject to change without...

Page 15: ...Ordercode 30690 Studio Beam CDM HCI 150 Dimensions 14 ...

Page 16: ... 2016 Showtec ...

Reviews: