background image

 

  

 

 

   

 

Ordercode: 50660 

 

PSA-16A3C 

 

 

Description of the device 

 
Features 

The Showtec PSA-16A3C is a power distributor providing real-time voltage and amperage information 
during your show. 

 

Input: 1 x CEE male 16A 3P+N+PE, 400V AC, 50/60Hz 

 

1 x 16A CEE output (on the front panel) 

 

6 x 16A CEE output, 2 per phase (on the rear panel) 

 

3 x 1-pin 16A, C-Type circuit breaker (MCB) 

 

Rated current: 16A 

 

Tripping curve: C-Type 

 

Poles: 1P 

 

Breaking capacity: 6kA 

 

Road suited housing and components 

 

Digital voltage & amperage monitoring per phase 

 

Housing: Powder-coated metal 

 

Color: Dark grey 

 

Dimensions: 

482 x 211 x 88 mm (LxWxH) 
19 inch x 2HE (LxH) 

 

Weight: 4,9 kg 

 

Frontside 

 

 

Fig.01 

01)

 

5-pin CEE power input

 

Connect to the three phase mains. Make sure that the total load connected to the PSA-16A3C does 
not exceed 16A per phase. The CEE input should be connected to the power source which is 
equipped with its own RCCB protection. 

02)

 

16A 3-pin CEE output 

Single-phase CEE output with a maximum load of 16A per socket, connected to L1 phase. Total load 
for all sockets together should not exceed 16A per phase. 

03)

 

L1 Main Circuit Breaker (MCB)

 

This circuit breaker will cut off the power supply if the load current per phase exceeds 16A. 

04)

 

L2 Main Circuit Breaker (MCB)

 

This circuit breaker will cut off the power supply if the load current per phase exceeds 16A. 

05)

 

L3 Main Circuit Breaker (MCB)

 

This circuit breaker will cut off the power supply if the load current per phase exceeds 16A. 

06)

 

L3 voltage & amperage LED display 

07)

 

L2 voltage & amperage LED display 

08)

 

L1 voltage & amperage LED display 

 
 

 

Summary of Contents for 50660

Page 1: ...PSA 16A3C V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50660 MANUAL ENGLISH...

Page 2: ...Instructions 2 Operating Determinations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 7 Installation 8 Set Up and Opera...

Page 3: ...ox and packing Your shipment includes Showtec PSA 16A3C User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow...

Page 4: ...exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and...

Page 5: ...Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Connection with the Three Phase Power Network Connect t...

Page 6: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Page 7: ...to the three phase mains Make sure that the total load connected to the PSA 16A3C does not exceed 16A per phase The CEE input should be connected to the power source which is equipped with its own RCC...

Page 8: ...side should not exceed 16A per phase 11 CEE L2 Output 3 pin CEE socket Maximum load 1x 16A per socket Total load for both sockets on L2 together should not exceed 16A per phase 12 CEE L2 Output 3 pin...

Page 9: ...s have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformat...

Page 10: ...0V AC 50 60Hz Circuit breaker 3 x 1 pin 16A C Type Electro mechanical effects IP rating IP20 Housing Powder coated metal Rated current 16A Breaking capacity 6kA Color Dark grey Voltage and amperage in...

Page 11: ...10 Ordercode 50660 PSA 16A3C...

Page 12: ...2016 Showtec...

Reviews: