background image

 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Do not open the device and do not modify the device. 

 

Never use anything to cover the ground contact. 

 

Never leave the device run without a lamp! 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. The 
Compact Power Lightset reacts very sensitive to movement. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes hot). 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only 
handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Only install the device with the hanging-bracket. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens or glass is obviously damaged, it has to be replaced. So that its functions are not 
impaired, due to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Lighteffect must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use fuses of same type and rating only. 

 

Allow time to cool down, before replacing lamp. 

 

The user is responsible for correct positioning and operating of the Compact Power Lightset. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation 
of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 
 

 
 

 
 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Summary of Contents for Compact Power Lightset V2

Page 1: ...Compact Power Lightset V2 ORDERCODE 30268...

Page 2: ...ely on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep...

Page 3: ...ams Auto Run Static Color One Compact Power Lightset Sound Control Multiple Compact Power Lightset Master Slave control Multiple Compact Power Lightset DMX control Fixture Linking Data Cabling Control...

Page 4: ...40 000 to 50 000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures...

Page 5: ...that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If the external c...

Page 6: ...yourself Always let the installation be carried out by an authorized dealer Procedure If the Compact Power Lightset is lowered from the ceiling or high joists professional trussing systems have to be...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...ct Built in programs DMX Control DMX 7 modes 2 3 4 7 8 14 15 Channel Mode Music controlled via built in microphone Master Slave function Variable in stand height 1200 2000mm Footswitch with 5m cable 3...

Page 9: ...trol 1 Plug the end of the electric mains power cord into a proper electric power supply socket 2 Turn on the music If device is set to Audio and you have pressed enter then the fixture will react to...

Page 10: ...signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug electric mains power cords...

Page 11: ...y result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Compact Power Lightsets on a DMX data link 30 fixtures Data Cabl...

Page 12: ...f the second Compact Power Lightset should be 1 15 16 A016 the DMX address of the third Compact Power Lightset should be 16 15 31 A011 etc Please be sure that you don t have any overlapping channels i...

Page 13: ...11 Menu Overview 1 Auto Program 2 DMX Address 3 Slave 4 Sound controlled 5 Static Color 6 Built in Programs...

Page 14: ...menus Number of Loops from 01 100 Speed from 01 99 and FL Fade Time from 00 99 Flash Frequency from 00 99 Use the SETUP button to scroll through the menu 2 DMX Mode With this menu you can set the DMX...

Page 15: ...Press the MODE button until the display shows 2 With this menu you can set 3 Static colors of the Compact Power Lightset You can choose Red Green or Blue by pressing the Setup button Use the Up Down...

Page 16: ...14 6 Built in Programs...

Page 17: ...l 3 Blue Channel 4 Red Channel 5 Green 0 255 Gradual adjustment Red from 0 100 0 255 Gradual adjustment Green from 0 100 0 255 Gradual adjustment Blue from 0 100 0 255 Gradual adjustment Red from 0 10...

Page 18: ...0 20 flashes sec 0 255 Gradual adjustment dimmer intensity from 0 100 0 255 Gradual adjustment Red from 0 100 0 255 Gradual adjustment Green from 0 100 0 255 Gradual adjustment Blue from 0 100 0 255 G...

Page 19: ...ram 13 210 219 Program 14 220 229 Program 15 230 239 Program 16 240 255 Sound controlled Note CH1 When CH1 is set to 0 79 CH2 has no function When CH1 is set to 80 239 CH2 controls the speed of the pr...

Page 20: ...CH2 15 10 249 Auto Program 250 255 Sound controlled 0 255 Gradual adjustment dimmer intensity from 0 100 0 255 Gradual adjustment Red from 0 100 0 255 Gradual adjustment Green from 0 100 0 255 Gradual...

Page 21: ...9 Program 11 190 199 Program 12 200 209 Program 13 210 219 Program 14 220 229 Program 15 230 239 Program 16 240 255 Sound controlled Note CH5 When CH4 is set to 0 79 CH5 has no function When CH4 is se...

Page 22: ...four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following...

Page 23: ...LR Out of the first fixture on the link i e signal is reversed Install a phase reversing cable between the controller and the first fixture on the link Fixtures reset correctly but some respond errati...

Page 24: ...240V 50Hz CE Fuse 1A 250V Music Control Dimensions 1200x295x60mm LxWxH Weight 8 7 kg Foot Controller Voltage 240V 50Hz CE Jack plug to connect to T bar with controller Cable length 5m Dimensions 500x1...

Page 25: ......

Reviews: