background image

 

  

 

 

   

 

Ordercode: 50667 

 

PSA-125A4C 

 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

aftersales@highlite.nl

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms  

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting.  
 

 

Summary of Contents for PSA-125A4C

Page 1: ...PSA 125A4C V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50667 MANUAL ENGLISH...

Page 2: ...uctions 2 Operating Determinations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Frontside 7 Backside 8 Installation 9 Set Up and...

Page 3: ...ox and packing Your shipment includes Showtec PSA 125A4C User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow...

Page 4: ...exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and...

Page 5: ...d Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Connection with the Three Phase Power Network Connect...

Page 6: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 7: ...V AC 50 60Hz Output 4 x CEE female 63A 3P N PE 400V AC 50 60Hz 4 x 3 pin 63A C Type MCB 1 x 4 pin 125A C Type main circuit breaker Rated current 125A Tripping curve MCB C type Poles 4P Breaking capaci...

Page 8: ...Main Circuit Breaker MCB This circuit breaker will cut off the power supply if the load current per phase exceeds 63A 06 Output 2 Main Circuit Breaker MCB This circuit breaker will cut off the power...

Page 9: ...t 3 3P N PE CEE socket maximum load 3 x 63A per socket Total load for all 4 sockets together should not exceed 125A per phase 12 CEE Output 4 3P N PE CEE socket maximum load 3 x 63A per socket Total l...

Page 10: ...owing points have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be a...

Page 11: ...pe main circuit breaker Output MCB 4 x 3 pin 63A C Type Electro mechanical effects IP rating IP20 Housing Powder coated metal Rated current 125A Breaking capacity 10kA Color Dark grey Voltage and ampe...

Page 12: ...2016 Showtec...

Reviews: