background image

 

  

 

 

   

 

Ordercode: 50667 

 

PSA-125A4C 

 

 

Backside 

 

 

Fig. 03 

 
09)

 

CEE Output 1

 

 

3P+N+PE CEE socket, maximum load 3 x 63A per socket. Total load for all 4 sockets together should 
not exceed 125A per phase. 

 
10)

 

CEE Output 2

 

3P+N+PE CEE socket, maximum load 3 x 63A per socket. Total load for all 4 sockets together should 
not exceed 125A per phase. 

 
11)

 

CEE Output 3

 

3P+N+PE CEE socket, maximum load 3 x 63A per socket. Total load for all 4 sockets together should 
not exceed 125A per phase. 

 
12)

 

CEE Output 4

 

3P+N+PE CEE socket, maximum load 3 x 63A per socket. Total load for all 4 sockets together should 
not exceed 125A per phase. 

 
13)

 

Power Input

 

 

Connect to the three phase mains input. Be sure that the total load connected to the PSA-125A4C 
does not exceed 125A per phase. You can monitor that by looking at the displays on the front panel. 
Make sure that the power source is equipped with its own RCCB. 

 
 

 

Summary of Contents for PSA-125A4C

Page 1: ...PSA 125A4C V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50667 MANUAL ENGLISH...

Page 2: ...uctions 2 Operating Determinations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Frontside 7 Backside 8 Installation 9 Set Up and...

Page 3: ...ox and packing Your shipment includes Showtec PSA 125A4C User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow...

Page 4: ...exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and...

Page 5: ...d Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Connection with the Three Phase Power Network Connect...

Page 6: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 7: ...V AC 50 60Hz Output 4 x CEE female 63A 3P N PE 400V AC 50 60Hz 4 x 3 pin 63A C Type MCB 1 x 4 pin 125A C Type main circuit breaker Rated current 125A Tripping curve MCB C type Poles 4P Breaking capaci...

Page 8: ...Main Circuit Breaker MCB This circuit breaker will cut off the power supply if the load current per phase exceeds 63A 06 Output 2 Main Circuit Breaker MCB This circuit breaker will cut off the power...

Page 9: ...t 3 3P N PE CEE socket maximum load 3 x 63A per socket Total load for all 4 sockets together should not exceed 125A per phase 12 CEE Output 4 3P N PE CEE socket maximum load 3 x 63A per socket Total l...

Page 10: ...owing points have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be a...

Page 11: ...pe main circuit breaker Output MCB 4 x 3 pin 63A C Type Electro mechanical effects IP rating IP20 Housing Powder coated metal Rated current 125A Breaking capacity 10kA Color Dark grey Voltage and ampe...