Operating Determinations
This device is not designed for permanent operation. Consistent operation breaks will ensure that the
device will serve you for a long time without defects.
The maximum ambient temperature
t
a
= 35°C must never be exceeded.
The relative humidity must not exceed 50 % with an ambient temperature of 35° C.
If this device is operated in any other way, than the one described in this manual, the product may
suffer damages and the
warranty becomes void.
Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc.
You endanger your own safety and the safety of others!
Connection with the Three Phase Power Network
Connect the device to the 3-phase Power Socket with a CEE-form power-plug.
Always make sure that the right color cable is connected to the right place.
International
EU Cable
UK Cable
US Cable
Pin
L1
BROWN
RED
BLACK
PHASE 1
L2
BLACK
YELLOW
RED
PHASE 2
L3
GREY
BLUE
BLUE
PHASE 3
N
BLUE
BLACK
WHITE
NEUTRAL
YELLOW/GREEN
GREEN
GREEN
PROTECTIVE GROUND
Make sure that the device is always connected
properly
to the earth!
Improper installation can cause serious injuries to people and/or damage of property !