background image

 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never run the device without lamp! 

 

Never ignite the lamp if the objective-lens or any housing-cover is open, as discharge lamps may 
expose and emit a high ultraviolet radiation, which may cause burns. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not open the device and do not modify the device. 

 

Do not switch the device on and off in short intervals, as this would reduce the system’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle the 
power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord 
from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If one of the lamps is obviously damaged, it has to be replaced. So that its functions are not impaired, 
due to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified engineer 
inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Light effect must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use lamps and fuses of same type and rating only. 

 

Allow time to cool down, before replacing lamp. 

 

The user is responsible for correct positioning and operating of the Sunstrip Active. The manufacturer 
will not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor 
to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase.

 

 
 
 
 

 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Summary of Contents for Sunstrip Active MKII

Page 1: ...Sunstrip Active MKII ORDERCODE 30714 ...

Page 2: ...ign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighting equipment Always get the best with Showtec Thank you...

Page 3: ... Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11 Menu Overview 12 Control Modes 12 DMX Mode 12 Setting the Channel Mode 13 CHASE Mode 13 Auto 13 Full 13 Program direction Normal Reverse 14 Selecting the Chase Speed 14 Selecting the Intensity Dimming Mode 14 Selecting your own welcome text logo editing 14 DMX Channels 15 1 Channel 15 2 Channels 15 5 Channels 15 10 ...

Page 4: ...h the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the device To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safet...

Page 5: ...before cleaning Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is dam...

Page 6: ...ty issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Sunstrip Active is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Sunstrip Active with the mounting bracket to the trussing system The Sunstrip Active must never be fixed swinging freely in the room Th...

Page 7: ...hod to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the g...

Page 8: ...ur clamp in any desired position For optimal creativity we recommend the special multibracket 30713 Power Input 230V 50Hz Power Consumption 500W Control 16 Built in Programs Sound Active Master Slave DMX Control Display 4 Digits LED Power Connector Neutrik Powercon in output Data Connector XLR In Out 3 Pin DMX control via standard DMX controller 16 built in programs subject to Speed and Dimmer exc...

Page 9: ...tor sends the power to the next unit Max 20A 3 DMX OUT 4 LED Display 5 Mode Button 6 Menu Button 7 Up Button 8 Down Button 9 Power On Off 10 Fuse 6 3A 250V 5 20mm 11 DMX IN 12 Power Input Blue This connector is the input power for this unit Max 20A ...

Page 10: ... higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 4 screws on the front of the housing 2 Gently remove the metal housing 3 Read lamp instructions Do not touch the lamp bulb glass Push and turn the lamp Counter Clockwise and remove the lamp Oil on hands shortens the la...

Page 11: ...t onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Plug the end of the electric mains power cord into a proper electric power supply socket 3 Always use a safety cable ordercode 70140 70141 4 Use a 3 p XLR cable to connect the Sunstrip Active 5 Link the units as shown in figure 4 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in s...

Page 12: ... link Connecting more than 30 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended number of Sunstrips on a power link 240V 7 fixtures Maximum recommended DMX data link distance 100 meters Maximum recommended number of Sunstrips on a DMX data link 30 fixtures Data Cabling To link fixtures tog...

Page 13: ...address of the third Sunstrip should be 11 10 21 etc Please be sure that you don t have any overlapping channels in order to control each Sunstrip correctly If two or more Sunstrips are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu d001 Controlling After having addressed all Sunstrips you may now start operating these via y...

Page 14: ...starts blinking DMX Mode With this menu you can set the DMX address and the required channel mode You can only use this mode when you are using the device as a DMX Dimmer This function allows you to set your device as a 1 2 5 or 10 Channel DMX Dimmer 1 Press and hold the MODE button for 5 seconds until the display starts blinking Press the MODE or MENU button until the display shows DMX mode is in...

Page 15: ... light will be individually controlled by one DMX Channel Note Default setting is CH 10 this means 10 DMX Channels so every light is individually controllable CHASE Mode You can only use this mode when you are using the device as a Chaser The unit has 16 built in programs Auto and Full You can select any of these programs to create a chase for a lightshow You can also control the program s chase s...

Page 16: ... shows d followed by 3 digits 4 Use the UP DOWN buttons to change the dimmer setting from 000 100 5 A value of 000 means the weakest output intensity and a value of 100 means the highest output Selecting your own welcome text logo editing 1 Press and hold the MODE button for 5 seconds until the display starts blinking 2 Now press and hold the MODE button while pressing the following sequence UP UP...

Page 17: ...0 255 From black to brightest 0 to 100 5 Channels Channel 1 Dimmer intensity light 1 2 0 255 From black to brightest 0 to 100 Channel 2 Dimmer intensity light 3 4 0 255 From black to brightest 0 to 100 Channel 3 Dimmer intensity light 5 6 0 255 From black to brightest 0 to 100 Channel 4 Dimmer intensity light 7 8 0 255 From black to brightest 0 to 100 Channel 5 Dimmer intensity light 9 10 0 255 Fr...

Page 18: ... From black to brightest 0 to 100 Channel 5 Dimmer intensity light 5 0 255 From black to brightest 0 to 100 Channel 6 Dimmer intensity light 6 0 255 From black to brightest 0 to 100 Channel 7 Dimmer intensity light 7 0 255 From black to brightest 0 to 100 Channel 8 Dimmer intensity light 8 0 255 From black to brightest 0 to 100 Channel 9 Dimmer intensity light 9 0 255 From black to brightest 0 to ...

Page 19: ...ont of the housing 2 Gently remove the metal housing 3 Follow directions for installing a new lamp page 8 Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow the directions below to do so 1 Unplug the unit from electric power source 2 Insert a flat hea...

Page 20: ...e controller and the first fixture on the link Fixtures reset correctly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables...

Page 21: ...y 4 Digits LED Power Connector Neutrik Powercon in output Data Connector XLR In Out 3 Pin DMX control via standard DMX controller 16 built in programs subject to Speed and Dimmer except for Auto Full Dimmer 0 100 01 99 Chase speed adjustment Power Failure Memory Fuse Protection Built in Dimmerpack Digital Addressing 10x Osram Lamp Halopar 16 GU10 230V 50W 35 80418 Included Fuse T6 3A 250V Dimensio...

Page 22: ......

Reviews: