PNU
FUNCTION
PARAMETER
REMAP
50
Encoder position
Encoder position register, you can read or write this value.
(expressed in encoder steps)
This value counts all fronts of two encoder phases
From -2147483647 to 2147483647
RD/WR
51
Encoder mode
Set encoder mode
If Write 0
no encoder feedback.
You can read encoder
but the drive don’t
use it to control position
1
encoder enabled
without error detection
2
encoder enabled with
error detection
RD/WR
52
Set encoder pulse/revolution
From 0 to 2147483647
RD/WR
53
Set encoder fault steps
Set encoder steps to detect positioning error.
From 0 to 2147483647
RD/WR
54
Encoder Index search frequency
It defines the search index frequency
From 1 to 5000 Hz
RD/WR
55
Encoder index search mode
Indicate 4 modes to search index
0x01= search CW
0x02= search CCW
0x11= search CW and set position to 0
0x12= search CCW and set position to 0
RD