34 – MAX SPEED
DESCRIPTION
For JOG and position commands, set the target speed of the motor.
For Homing command, set the speed for the sensor search.
Value in step/sec, in full steps ( 200 = 60RPM )
35 – MIN SPEED
DESCRIZIONE
For JOG and position commands, set the start speed of the motor.
Per I comandi di Homing, imposta la velocità di disimpegno dal sensore.
Valore in step/sec, espresso in passi interi ( 200 = 60RPM )
26 – ACTUAL SPD
DESCRIPTION
Read the actual speed of the motor in RPM.
28 – AN IN 1
DESCRIPTION
Read the analog input 1 value, espresso in mV
29 – AN IN 2
DESCRIPTION
Read the analog input 2 value, espresso in mV
30-31 – ACTUAL POSITION
DESCRIPTION
Read the actual position, in step (20 bit)
32-33 – TARGET QUOTE
DESCRIPTION
Set the target quote for relative and absolute positioning (step)
36-37 – ENCODER
DESCRIZIONE
Read the pulse count from the external encoder.
25 – SETTINGS
BIT
OPERATIONE
DESCRIPTION
0
Enable limit sensors
0=limit sensors disabled 1=limit sensors enabled
1 ÷ 15
-
Riservati