SR501 EN Operation Manual
- 36 -
► Press “SET” button, hour “00” blinks on the screen
► Press “▲▼” to set hour of the start time
► Press “SET” button, minute “00” blinks on the
screen
► Press “▲▼” to set minute of the start time
►Press “SET” or “ESC” button to confirm.
►Press “▲” button to access the second time-section setting, repeat above
steps to set the start time and end time of the second and the third time-section.
Note:
1)
If it is needed to close one time-section, just set its start time and end time
at a same value (e.g. 10:00 starts, 10:00 ends)
2)
Under standby status, hold
“ESC” button to access the inquiry function,
there you can check the on or off status of this function. press
“
▲”
to check,
“OTF ON” indicates the timer function is activated. “ON” blinks
,
it indicates
the timer function is running.
6.8 TKPR Tank high temperature protection function
Description:
To prevent tank from damaging caused by high temperature, when tank
temperature rises to the switch-on protection temperature, default is 80
o
C,
water filling will be triggered, it will stop until tank temperature drops to 78
o
C
(default set is 2
o
C hysteretic) or water level is to 100%. When water is using
(water level is dropping), then water filling is delayed for 30 minutes to start.
(this tank protection function is time limited, it can only be triggered from
8:00-17:00).
Setup steps:
►Select main menu TKPR tank high temperature
protection function