Shure Incorporated
11/14
Dynamic Range
1 kΩ load
, @ 1 kHz
92
dB
Common Mode Rejection
10 to 100,000
kHz
45
dB
, minimum
Preamplifier Output Clipping Level
at 1% THD
–7 dBV
(0.5
V
)
Mute Switch
−50 dB
minimum
Logic Connections
LED IN
Active low (≤1.0V), TTL compatible. Absolute maximum voltage: -0.7V to 50V.
LOGIC-
OUT
Active low (≤0.5V), sinks up to 20mA, TTL compatible. Absolute maximum voltage: -0.7V to 24V (up
to 50V through 3kΩ).
Cable
6.1
m
(20
ft
), attached, unterminated, three shielded audio pairs and three shielded conductors for logic control
Net Weight
594
g
(1.3
lbs
)
Environmental Conditions
Operating Temperature
–18–
57°C (0
–
135°F)
Storage Temperature
–29–74°C (–20–
165°F)
Relative Humidity
0
–
95%
Power Requirements
MX396/C-DUAL
48
–
52
V DC
, 19.0
mA
MX396/C-TRI
48
–
52
V DC
, 22.0
mA
Summary of Contents for Microflex MX396
Page 2: ...Shure Incorporated 2 14...
Page 12: ...Shure Incorporated 12 14...