background image

Installation

 

1.  Turn off all power to fan. 
2.  If it is a new installation, cut and frame out a  

14” x 14” hole.  Prepare all wiring and fusing per 
specifications. 

3.  Remove old fan inside and out. 
4.  Carefully remove all old roof sealant.  Surface 

must be clean and dry. 

5.  Check fit of new fan inside and out. 
 

--Hinge must face toward front of the RV. 

 

--Verify correct wiring size and length. 

 

--Check inside ceiling flange clearance.        

 

 

Supplied trim fits roofs 3-1/2” to 5-1/2” thick. 

 

 

Trim can be cut or call SHURflo for other sizes 

 

--Holes in roof exterior can be filled with wood  

 

  putty or sealant to ensure a better seal later. 

6.  Apply 1” Butyl putty tape around mounting hole 

pattern on roof side of fan chassis. 

 

--Center the tape over the mounting holes. 

7.  Place unit on roof and check alignment inside 

and outside. 

 

--Hinge must be to the front of the RV. 

8.  Screw unit to roof with 28 screws. 
 

--Screws removed from previous unit can be  

 

  used. 

9.  Seal all edges and screws with silicone sealant, 

or use EPDM Rubber roof sealant for rubber 
roofs. 

 

--Do not allow sealant to contact dome hinge or  

 

  rain sensor. 

10. Check wire polarity and connect wires inside of 

coach. 

 

--Red wire is positive (+).   

 

--Black wire is negative (-). 

 

--Polarity must be correct or damage to circuit  

 

  board will result! 

11. Test hand crank by pulling down on crank and 

turning CW to open dome.   

 

--Crank must be in upper position for power  

 

  operation. 

 

--Dome motor must be stopped before moving  

 

  hand crank in or out. 

12. Place lower trim in place and secure with 4 

screws provided. 

 

--Hand crank should be facing front. 

13. Turn on main power to unit. 
14. Place 9V battery in Fan Remote Commander. 
15. Reset remote and test unit.  See Section on 

Resetting The Remote. 

 
 
 
 

 
 
 

                        

Ceiling View of Fan

 

 
 
 
 
 
 
 
 
 
 
 
 

Operation 

HAND DOME OPERATION 

Pull down on manual crank and turn to open or 
close the dome by hand.  Push crank up to lock 
gears for power dome operation.

 

MANUAL MODE 

Press Fan Hi 1 or Fan Lo 3 buttons or Dome Open 
4, Stop 5 or Close 6 buttons to operate in Manual 
Mode.   

Changing Fan Direction 

Press Exhaust/Intake button 7 to change direction. 

AUTO MODE 

Press Cooler button 8 or Warmer button 9 on the 
remote to lower or raise thermostat temperature 
setting.  Dome will open and fan will start only above 
selected operating temperature.  When temperature 
drops 5° F below set point, dome will close and fan 
will shut off.  Dome will automatically open and fan 
will restart when temperature set point is reached.   

Changing Fan Direction 

Press Exhaust / Intake button 7 to change fan 
direction. 

Adjusting Fan Speed or Dome Opening 

Press Fan Hi button 1 or Lo  button 3 to adjust fan 
speed.  Press Dome Open button 4 or Close button 
6 to adjust dome opening.  Press Dome Stop button 
5 to stop dome in desired position. 

To Exit Auto Mode 

To exit Auto Mode press Fan Off button 2.  Dome 
will close and fan will power off.  Holding down 
Cooler Button 8 will exit Auto Mode with fan running. 

Rain Sensor 

This unit is equipped with a rain sensor to 
automatically shut off the fan 

when rain is detected 

in Auto Mode only

.  Sensor is not activated in 

Manual Mode. 
When rain sensor is activated, dome will close and 
unit will turn off.  Fan will not restart when rain 
sensor dries out.  Fan unit must be restarted in 
Manual or Auto Modes.

 

 

Hand Crank 

911-724-A  04/05 

 

 

 

 

 

 

 

 

 

 

 

 

page 3 of 4

 

 

Fan and Remote Cleaning

 

Turn off all power, and remove screen by 
unsnapping 4 fan clips.  Wipe fan and remote with 
damp rag with mild detergent only.  Dry unit after 
wiping. Do not immerse fan or remote in water.   
To replace screen, align clips and snap into place. 

NEVER OPERATE FAN WITH SCREEN REMOVED! 

 

Screen Clips (4) 

Reset 

RESET 

Summary of Contents for Comfort Air 275-3330

Page 1: ... 9 Volt DC Remote Control Battery 1 Installation and Operation Manual Location Fan must be installed with the hinge facing the direction of travel Locate bi directional fan at least 3 feet from any exhaust vent l Do not install fan in cooking area Important Information SHURflo recommends professional installation Please read the entire manual before attempting installation This unit requires 12 VD...

Page 2: ...ermostat temperature setting sBattery Compartment Rear of Remote Slide open rear compartment to replace 9V battery Resetting The Remote Never reset remote control with screen removed It may be necessary at times to reset the remote to match the Comfort Air unit This would be done to make one remote work for 2 fans to make 2 fans operate from different remotes or when purchasing a new remote for an...

Page 3: ... of Fan Operation HAND DOME OPERATION Pull down on manual crank and turn to open or close the dome by hand Push crank up to lock gears for power dome operation MANUAL MODE Press Fan Hi 1 or Fan Lo 3 buttons or Dome Open 4 Stop 5 or Close 6 buttons to operate in Manual Mode Changing Fan Direction Press Exhaust Intake button 7 to change direction AUTO MODE Press Cooler button 8 or Warmer button 9 on...

Page 4: ...owner by another party Some states and provinces do not allow limitations on how long an implied warranty shall last or do not allow the exclusion or limitation of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and youmay also have other rights that may vary from state to state FCC Statement This equipment...

Reviews: