Chapter 5 Equipment
T
-900 series
5-5
0093142132-00
Install with four bolts
Spring washer
Flat washer
Flat washer
M12 nut
M12 bolt
Installation base
Electric erosion preventive washer
Electric erosion preventive washer
Scanner installation foot
Specification of bracket thickness-wise installation bolt (In case of open antenna)
Thickness of bracket
Bolt for fixing the antenna
Material
Remarks
1 - 4 mm (0.04 – 0.16 in)
M10x45 (pitch 1.5mm)
stainless
4 - 9 mm (0.16– 0.35 in)
M10x50 (pitch 1.5mm)
stainless
9 - 14mm (0.35 – 0.55 in)
M10x55 (pitch 1.5mm)
stainless
Included in accessories
14 – 19 mm (0.55 – 0.75in)
M10x60 (pitch 1.5mm)
stainless
Installation of Antenna
1.
Remove the protective cap covered on the output of the scanner unit rotational shaft.
2.
Remove four bolts tentatively fixed to the base of the aerial and install the scanner unit to the
rotational shaft. Align the direction of antenna opening side (
SI-TEX
seal is affixed.) with the
arrow on the rotational shaft.
3.