Chapter 5 Equipment
T
-900 series
5-7
0093142132-00
5.
Remove the holder plate for fixing
the cable and the rubber ring
Thread the cable through the
leading opening
Insert the rubber ring from both
sides of the antenna cable, thread
it through the holder plate and fix it
to the antenna with the screws.
Connect the 7-pin connector of the
cable to X1 of the printed circuit
board.
6.
Install the shield cover. At this
moment, install the shield of the
cable in the groove, using the
shield cover. But, be careful for the
cable not to be caught by the unit
and the cover.
7.
Install the upper radome with
caution not to touch the radiator.
Orient the cover as shown in the
illustration at the right hand side. 3
markings indicating the screw
positions are marked on the upper
and lower radomes respectively.
Install the radome, aligning these
markings.
Radome Antenna (4kW)
1.
Confirm that the power of the scanner unit is turned off.
Install the antenna cable to the connector J5 at the rear of the display unit.
2.
Remove the upper radome of the scanner unit, lifting upward not to touch the aerial inside.
(4 pieces of fixing screw)
3.
Peel off the tape fixing the aerial.
4.
Remove the shield cover at the stern side. (4 piece of fixing screw)
5.
Remove the holder plate for fixing the cable and the rubber ring
Thread the cable through the leading opening
Insert the rubber ring from both sides of the scanner unit, thread it through the holder plate and fix
it to the aerial with the screws.
6.
Connect the 7-pin connector of the cable to X11 of the printed circuit board and the 9-pin
connector to X11 respectively.
7.
Install the shield cover. At this moment, install the shield
of the cable in the groove, using the shield cover. But, be
careful for the cable not to be caught by the unit and the
cover.
Install with four bolts.
Stern
Aerial
Shielding cover
Cable shield
Holder plate
Antenna cable
Radome (bottom)
Rubber ring