Manu_ENG_UFO_ rev. 0_04_2012
pag. 16
PUT IN OPERATION and FIRST START-UP
(for all the models)
When you first start the appliances is important to make some preliminary checks to
ensure its proper running; operations listed below are considered essential:
make sure there are no losses in the gas line and that is properly sized
check that the pressure and type of gas used comply with the data on the plate
of the characteristics of the appliance
check the correct mounting of gas group, gas valve and flame control, (only for
appliance UFO EB /08, with electronic start-up)
check that the power electric line has been correctly sized, which has been respected
phase - neutral polarity and that the cable grounding is connected (only for appliance
UFO EB /08, with electronic start-up)
make sure the mechanical installation (supports) of the appliance have been properly
carried out and that the connections bolts are tight
use only steel materials, since heat is transferred from appliances to supports