background image

 

 

e005 OLIMPO 

 

 

ver. 00 

 
 

 
User’s manual 

pag. 21 di 29 

Printed in 

e005-di OLIMPO (eng).doc 

 

Siap+Micros S.r.l. 

3  Technical features 

 

Input/output  ...................

-

 

Analogic inputs : 

n. 8  a 12 bit + n. 4 analogic input/Pt100 a 18 bit with differential 

input  

-

 

Analogic input range: 

+/- 2V each input 18 bit  0-2V each input a 12 bit 

-

 

Analogic output: 

n. 4  a 12 bit (at request) 

-

 

Digital input: 

n°3 channels On/Off optoisolated, frequency max 30Hz 
n°2 channels optoisolated at 2500Vdc with a rebound proof filter for 
period measuring (max 900s),frequency (max 1 KHz), counter , duty 
cycle, state of input 

-

 

Open collector outputs:  n. 8 (Vmax=50V, Imax=200mA) 

Connectable devices .....

-

 

Sensors with tension outputs  (typical 0- 2Vdc) 

-

 

Sensors with electric current outputs (typical 4-20mA) 

-

 

Resistive sensors (Pt100) 

-

 

Sensors/equipment with open contact outputs open/closed  (ON/OFF) 

-

 

Sensors  with  impulse  outputs  (counter,  frequency  meters,  pluviometer,  anemometers, 
etc…) 

-

 

Equipment with analogic

 

inputs ( paper recorders, actuators, etc …) 

-

 

Command relay  

Communication .............

-

 

N°.2 serial ports representable like RS232 or RS485 

Data capacity .................

-

 

Resident memory  (internal)  of 384 KB 

-

 

Extra safety memory extractable Memory card ranging from 8 to 64MB 

Main power  ....................

-

 

Main power network 220Vac  50Hz (P max=5W) 

-

 

Battery  12Vdc 

-

 

By a solar panel 

-

 

By a wind (aeolian) generator 

Typical consumption .....

-

 

15mA (stand by); 45mA (continuous functioning) 12Vdc 

Other information...........

-

  Calendar clock with an automatic handling for a leap year 

-

  Watch dog 

-

  Keyboard with a membrane with 46 multifunction keys 

-

  Display of  2 or 16 lines and 40 characters 

-

  Dimensions (lxhxp) 400x500x200mm 

-

 

Weight < 10 Kg excluding the tampon battery

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for e005 OLIMPO

Page 1: ...MPO Data Collection Unit User s Manual ver 5 12 SIAP MICROS S r l Via del Lavoro 1 tel 39 0438 491411 fax 39 0438 401573 I 31010 Castello Roganzuolo email info siapmicros com di San Fior TV www siapmi...

Page 2: ...10 3 Configuration of the parameters 6 1 11 Acquisition cycle 6 1 12 The registration 7 1 13 The registration autonomy 8 1 14 Substitution of the MEMORY CARD 8 1 14 1 Data format 8 1 15 Record format...

Page 3: ...he unit should be connected to an electric earthing or of safety by using a three wired AC power cable This cable should be connected to Complied electric socket equipped with three contacts The unit...

Page 4: ...g transport procedures we recommend that the unit be kept in an upright vertical position without shaking it 1 4 Unpacking Before unpacking the unit and installing it ensure that the following precaut...

Page 5: ...n and where it can t damaged or moved due to inexperience or distraction Do not place any other objects or things which weigh more than a few kilograms on top of the unit Do not place the unit on top...

Page 6: ...ser s manual pag 4 di 29 Printed in e005 di OLIMPO eng doc Siap Micros S r l 1 8 The panel description Display Membrane keyboard Memory card Red Led PWR COM1 RS232 Connection to PC PWR Switch COM2 RS2...

Page 7: ...e SETUP procedures by pressing the button indicated as S as written on the display If no letters are digited the Olimpo Main Unit will carry out the preset acquisition procedures 1 10 Setup At any mom...

Page 8: ...d on the display will appear Choose from the memory area to reset to zero by digiting the relative number 0 internal memory RAM and the memory card ATA internal memory RAM e memory card ATA 1 Internal...

Page 9: ...3 5 Kbyte File 4 5 Kbyte File 5 5 Kbyte File 6 300 Kbyte File 7 1 Kbyte File 8 1 Kbyte File 9 1 Kbyte The acquired data taken by the Olimpo Main Unit are memorized on File 6 while the instant data ar...

Page 10: ...wait for approx 10 15 seconds before verifying the acquisitions N B The insertion or the extraction of the MEMORY CARD without having switched off the unit could cause a malfunctioning of the Main Uni...

Page 11: ...e data is recorded in the suitable memory area They are recorded in a sequence of characters ASCII The memorizing procedures of the data depend on the specific type of data in question These modules a...

Page 12: ...event memorized in the record with the mm format aa Year of the event memorized in the record with the aa format 0 A constant code which identies this type of record Format for the Statistical Data Mn...

Page 13: ...DEVIATION of the parameter identified by the field as id G VARIANCE of the parameter identified by the field as id H SUMMATION of the parameter identified by the field as id L MINUTE OF THE MINIMUM s...

Page 14: ...nt Gg 02 Month of the event Mm 96 Year of the event Aa 0 The constant code identified by the Statistical Data 0 M03 Means that 3 Blocks which represent 3 parameters will follow Mnum_input 1 Id of the...

Page 15: ...tant Data relating to every parameter of measurement The Body of the record format is therefore made up by repeating a block of information as many times as the parameters which are to be represented...

Page 16: ...ht undertake and the next field value in the specific application of Instant Data constant the meaning the next field has undertaken value T TYPE analogic or digital of the parameter identified by the...

Page 17: ...be structured like this id T value_1 A value_2 S value_3 The three sections shown do not have to be positioned in a precise order but it would be advisable to position as shown above Depending on the...

Page 18: ...cates that the Instant data has been acquired correctly value 2 The ID of the second parameter id T Specifies that the next field is the type of the parameter constant 0 An analogic parameter value A...

Page 19: ...2BODY The Body of the record format contains the Data in Alert regarding each parameter in alarm The Body of the record format is therefore composed of a repetition of a block of information which ha...

Page 20: ...eld constant and the following field value might undertake in the special application of Data in Alert constant The meaning that the following field has undertaken value T TYPE analogic or digital of...

Page 21: ...t have to be positioned in a precise order however it is advisable to position as shown above 1 17 3TERMINATOR Finally the terminator is a field which identifies the end of the record format The termi...

Page 22: ...um_input 10 The ID of the parameter in alarm id T Specifies that the following field is that type of parameter constant 0 An analogic type of parameter value W Indicates that the following field is th...

Page 23: ...outputs typical 4 20mA Resistive sensors Pt100 Sensors equipment with open contact outputs open closed ON OFF Sensors with impulse outputs counter frequency meters pluviometer anemometers etc Equipme...

Page 24: ...risk analysis carried out described in the following pages the following European directives have emerged regarding this product Original Directive Directive with variations or additions Title Referen...

Page 25: ...within the field of application of this present decree unless they are commercially available 3 The radio apparatus used by the amateur radio operators do not fall within the field of application of t...

Page 26: ...for a correct use are Reference temperature 20 C Temperature of use 30 C 60 C Relative maximum humidity allowed 100 not condensed Storage temperature 30 C 70 C Storage humidity 90 Requested special tr...

Page 27: ...have been applied and or technical specifications here below have been indicated CEI EN 61010 1 Safety regulation for electrical apparatus of measurement control and for laboratory use CEI EN 611131...

Page 28: ...NE ALIMENTATORE 14 V KAT 600 MONITOR BATTERIA N N 12V BATTERIA 1 2Ah 1 2 4 6 5 3 PS CARICO BATT GND PS ALIM BATT ALIMENTAZIONE DISPLAY ALIMENTAZIONE OLIMPO ALIMENTAZIONE GSM SU PANNELLO FRONTALE INGRE...

Page 29: ...mber of the station memorized on the Record format Refer to the software manual of OLIMPO SW for the running instructions of the station 1 2 Downloading instructions Turn off the OLM LMC Connect the c...

Reviews: