background image

Annual Maintenance

Following as for routine and monthly maintenance, once a year you should
service your pump by using Blagdon Pond Pump Cleaner, (this may need to 
be done more frequently in hard water areas).

Dismantle pump and examine all parts for wear or damage, replacing any
parts that show obvious wear and/or damage. (See “Getting to know your
pump” for parts/description and replacement parts codes.) Particular care
should be taken to examine the cable entry point and the cable; if there is any
sign of damage the pump should be discarded.  On models 1500, 2500, 3250
and 4000 also check ‘O’ ring seal (see diagram below)

Winter Storage

The pump can be run in the pond during the winter but care should be taken
to ensure that it is fully immersed and cannot freeze solid. If the pump is not
used during the winter, follow annual maintenance procedure and store frost-
free in the house or garage until spring.

MAINTENANCE & CLEANING

10

11

MAINTENANCE & CLEANING

Remove impeller cover by pulling gently upwards from the base.

Remove impeller from pump motor.  Wash parts with fresh water carefully.

Monthly Maintenance

Following as for Routine Maintenance (steps 1 to 3).

800 MODEL: 

MONTHLY MAINTENANCE

To check the ‘O’ ring
seal, turn impellor
housing anti-clockwise
and pull away pump
motor. Remove and
check seal.

Replace carefully.

1500/2500/3250/4000 MODELS: 

ANNUAL MAINTENANCE

HT Multi 6000 model only, remove screw.

Remove impeller cover by turning anti-clockwise to 
release lock. Then pull firmly away from pump motor.

Carefully remove impeller shaft locator and washer. Place in a safe place.

Remove impeller from pump motor. Wash parts with fresh water carefully.

1500/2500/3250/4000/6000 MODELS: 

MONTHLY MAINTENANCE

2

1

2

1

1

1A

2

3

2

2

& 3

1

1A

Multi Instructions 3250 AW  23/3/06  10:23 am  Page 13

Summary of Contents for BLAGDON HYDRATECH MULTI 800

Page 1: ... by Blagdon s award winning range of water gardening equipment As a result Blagdon s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike Blagdon The Pond Masters The name you can rely on Interpet Dorking Surrey RH4 3YX Leaflet Code POS 0008 IMPORTANT Please attach proof of purchase to this manual and file in a safe place THE POND MASTERS GUIDE TO HYDRATECH M...

Page 2: ...mp in pond 8 9 Maintenance and cleaning 9 Cleaning 9 Step by step guides 9 11 Routine maintenance 9 Monthly maintenance 10 Annual maintenance 11 Winter storage 11 Troubleshooting 12 Troubleshooting and maximising performance 12 Faults problem procedure 13 Consumer advice contact details 13 Returning faulty pumps 13 Guarantee 13 CONTENTS GETTING TO KNOW YOUR HYDRATECH MULTI PUMP OPENING AND CLOSING...

Page 3: ...6 Pump outlet hole N A 7 Pump support brackets N A 8 Filter cage hinges N A 1 2 4 5 6 7 8 3 GETTING TO KNOW YOUR HYDRATECH MULTI PUMP HYDRATECH MULTI 800 Hydratech Multi 800 No Part Description Spare Code 1 Pump motor unit N A 2 Impeller complete 1040815 3 Pump outlet N A 4 Impeller cover N A 5 Water bell 1040747 6 Double Daisy 1040747 7 23cm telescopic riser pipe 1040761 5 7 6 2 1 3 4 Parts 5 and...

Page 4: ...1040808 10 Water bell large 1014144 11 Daisy 3 stage 1040754 1 2 4 5A 5 5A 6 3 7 9 10 11 8 GETTING TO KNOW YOUR HYDRATECH MULTI PUMP HYDRATECH MULTI 6000 No Hydratech Multi 6000 Part Description Spare Code 1 Pump motor unit N A 2 Pump outlet N A 3 Impeller housing N A 4 Shaft locator 1017671 5 Ceramic shaft and locator 1017664 6 Impeller only 1017626 7 Impeller cover O ring 1017640 8 Impeller cove...

Page 5: ... a metal or plastic conduit to protect the cable Attention has been drawn to the fact that special rules may exist concerning the installation of your pond pump i e local building regulations These pumps must not be used in swimming pools or areas where people are in contact with the water Always disconnect the mains electricity supply whilst the equipment is being installed repaired maintained or...

Page 6: ... pre filter cleaning Fountain Make sure there is ample cable from mains supply Place pump in desired location Adjust telescopic riser pipe so fountain head is above surface of the pond Fountain height can now be adjusted see Adjusting dual control T piece diagram below not 800 model See Getting to know your Hydratech Multi for parts and descriptions Tip Ensure that any fountain waterfall filter or...

Page 7: ...used during the winter follow annual maintenance procedure and store frost free in the house or garage until spring MAINTENANCE CLEANING 10 11 MAINTENANCE CLEANING Remove impeller cover by pulling gently upwards from the base Remove impeller from pump motor Wash parts with fresh water carefully Monthly Maintenance Following as for Routine Maintenance steps 1 to 3 800 MODEL MONTHLY MAINTENANCE To c...

Page 8: ...mited to replacement of the faulty product only no other costs will be reimbursed This guarantee is not transferable and does not affect your statutory rights This guarantee does not confer any rights other than those expressly set out above Excludes impeller which may require replacing annually If any parts need replacing spares are available from your retailer GUARANTEE IMPORTANT Problem Low flo...

Reviews: