- Select the "OPEN" icon and load the file with the extension .bin of the firmware version to be updated previously downloaded from the
network.
- Select the COM serial port where the programming cable is connected to the PC.
- Select the "START" icon to start programming.
- When the message "OK 100%" appears, this means that the programming has been completed successfully.
- At the end of programming, press the "Close" key to close the program, switch off the machine and return the deep-switch to its original
position (all the switches are OFF).
- In the event that error messages are displayed, check the correct wiring of the serial cable and repeat the programming procedure by
switching the machine off and on again.
IMPORTANT: when the board FIRMWARE update is complete, test the E2PROM to reset the calibration parameters as described in the paragraph “E2PROM
MEMORY RESETTING PROGRAMME”.
After this test, the following operations must be repeated in this order:
1. configure the machine based on the version as described in the paragraph “MACHINE SOFTWARE CONFIGURATIONS”;
2. internal sensor calibration as described in the paragraph “INTERNAL SENSOR CALIBRATION”;
3. Calibrate the external sensor, if installed;
4. machine sensitivity calibration;
5. resetting the group, see paragraph “shaft assembly resetting”.
Summary of Contents for S 64E
Page 43: ...Fig 20 fig 21...
Page 45: ......
Page 46: ...SECOND VERSION OF PNEUMATIC SYSTEM from April 2016...
Page 47: ...THIRD VERSION OF PNEUMATIC SYSTEM from March 2017...
Page 48: ...FOURTH VERSION OF PNEUMATIC SYSTEM...
Page 50: ...PEAL 32F...
Page 51: ......
Page 52: ...MBUGRF 2 LIGHT...
Page 53: ......
Page 54: ...COMIM Cod 4 119446B_EN 05 2018...