Fig.9d
14. PICK-UP REPLACEMENT AND ADJUSTMENT
To replace the pick-ups, follow this procedure:
- Disconnect the connection of the pair of pickups from the MBUGRF board (D fig. 3);
- loosen the pick-up pre-load springs completely (A, Fig. 10);
Fig. 10
- Unscrew the two M10 dowels and replace the pick-ups (B, Fig. 10) with the new ones;
- assemble the new pair of pick-ups, ensuring that the spheres are correctly positioned inside the appropriate niches, and that the pick-up
marked with the letter I (internal) is assembled on the right and the one with the letter E (external) is on the left (assuming you will work from
in front of the machine);
- tighten the fixing dowels so that the pick-ups are slightly rubbed;
- tighten the locknuts as far as the blocking point, then unscrew them slightly (by about one side of the hexagon) so that the Belleville washers
are working.
Summary of Contents for S 64E
Page 43: ...Fig 20 fig 21...
Page 45: ......
Page 46: ...SECOND VERSION OF PNEUMATIC SYSTEM from April 2016...
Page 47: ...THIRD VERSION OF PNEUMATIC SYSTEM from March 2017...
Page 48: ...FOURTH VERSION OF PNEUMATIC SYSTEM...
Page 50: ...PEAL 32F...
Page 51: ......
Page 52: ...MBUGRF 2 LIGHT...
Page 53: ......
Page 54: ...COMIM Cod 4 119446B_EN 05 2018...