Further topics
•
"Error and status indications on the 7segment display", page 114
•
"Error and status indications of the LEDs", page 113
8.3
Test notes
8.3.1
Tests before initial commissioning
Overview
Check the protective device as described below and in accordance with the applicable
standards and regulations.
Important information
WARNING
Hazard due to unexpected starting of the machine
Until all the tests have been successfully completed, it is possible that the machine,
system or the protective device does not yet behave as planned.
b
Make sure that nobody is put at risk during initial commissioning of the machine.
Approach
b
Make sure that there are no persons in the hazardous area during initial commis‐
sioning.
b
Check the effectiveness of the protective device mounted to the machine, using all
selectable operating modes as specified in the checklist in the annex,
list for initial commissioning and commissioning", page 148
b
Check the effectiveness of the protective device as per the daily check,
check of the protective device by authorized and specialist personnel", page 107
b
Make sure that the operating personnel of the machine protected by the safety
laser scanner are correctly instructed by qualified safety personnel before being
allowed to operate the machine. Instructing the operating personnel is the respon‐
sibility of the machine owner.
b
Ensure that the information label
Notes on daily check
is affixed to the machine in
a place where it is clearly visible for the operators. The information label is
included with the safety laser scanner on delivery. Ensure that the operators are
given the opportunity to properly perform this daily check.
b
The annex to this document includes a checklist for review by the manufacturer
and installer. Use this checklist as a reference before commissioning the system
for the first time.
b
Document in a clear manner the settings for the safety laser scanner, and the
results of the testing during initial commissioning. For this purpose also print out
the complete configuration of the safety laser scanner (including protective field
shapes) and include these with the documentation.
NOTE
•
Use the
Create diagnostic dump...
function in the CDS (right click on the COM inter‐
face to which the safety laser scanner is connected). You can keep these data as a
backup and in this way document the state during initial commissioning at any
time.
•
Your SICK representative will be pleased to provide you with advice on initial com‐
missioning.
8
COMMISSIONING
104
O P E R A T I N G I N S T R U C T I O N S | S300
8010948/ZA21/2020-06-18 | SICK
Subject to change without notice