When switching on the safety laser scanner in an EFI system, the following message
appears briefly on the 7-segment display:
•
at the host
•
at the guest
NOTE
In an EFI system with an S3000, the S300 must be configured as the guest. It must not
be configured as the host.
3.2.8.1
Interoperability of variants
In the course of further developing the safety laser scanner, additional functionality
such as the triple field technology has been implemented in the devices. The latest
devices are therefore not fully compatible with the safety laser scanners already in the
field.
To ensure the compatibility of the devices, S300 safety laser scanners with
firmware ≥ 02.10 and serial number > 12210000 can be operated in compatibility
mode. The following tables show which devices can form an EFI system.
Interoperability with safety laser scanners
Table 3: Interoperability with safety laser scanners
S3000 S
tand
ard
S3000 A
dv
anc
ed
S3000 Pr
of
es
sional
S3000 R
emo
te
S3000 Exper
t
S300 S
tand
ard
S300 A
dv
anc
ed
S300 Pr
of
es
sional
S300 Exper
t
S300 Mini S
tand
ard
1)
S300 Mini R
emo
te
S300 Standard
l
l
l
l
l
l
l
l
l
–
l
S300 Advanced
l
l
l
l
l
l
l
l
l
–
l
S300 Professional
l
l
l
l
l
l
l
l
l
–
l
S300 Expert
l
l
l
l
l
l
l
l
l
–
l
1)
This device does not have an EFI interface so it cannot be used in an EFI system.
l
= EFI system supported
– = EFI system not supported
Interoperability with safety laser scanners in compatibility mode
Table 4: Interoperability with safety laser scanners in compatibility mode
S3000 S
tand
ard
S3000 A
dv
anc
ed
S3000 Pr
of
es
sional
S3000 Pr
of
es
sional
S3000 R
emo
te
S3000 Exper
t
S300 S
tand
ard
1)
S300 A
dv
anc
ed
S300 Pr
of
es
sional
S300 Pr
of
es
sional
S300 Exper
t
S300 Exper
t
S300 Mini S
tand
ard
1)
S300 Mini R
emo
te
S300 Standard
–
–
–
–
–
–
–
–
–
–
–
–
–
–
S300 Advanced
l
l
l
l
l
l
–
l
l
l
l
l
–
–
S300 Professional
l
l
l
l
l
l
–
l
l
l
l
l
–
–
3
PRODUCT DESCRIPTION
22
O P E R A T I N G I N S T R U C T I O N S | S300
8010948/ZA21/2020-06-18 | SICK
Subject to change without notice