This device does not have an EFI interface so it cannot be used in an EFI system.
l
= EFI system supported
– = EFI system not supported
Further topics
•
3.2.8.2
Special considerations for EFI systems
Input signals
In an EFI system, the input signals for monitoring case switching are applied to the
inputs of the host or a safety controller. The guest communicates with the host via EFI
and receives the input information regarding monitoring case switching from the host.
Monitoring case switching
In an EFI system, the host determines the number of possible monitoring cases. If you
have configured an S300 with a higher-level device (S3000 or higher specification
S300 or sens:Control device) as the guest, more monitoring cases may be available
depending on the system configuration.
Example
You are using an S300 Advanced as a guest for an S300 Professional. The S300 Pro‐
fessional has been configured with 8 monitoring cases. In this case 8 monitoring cases
will also be available on the S300 Advanced.
Internal or external OSSDs
In an EFI system, you define which output signal switching device (OSSD) is switched
when there is an object in the protective field.
The effectiveness of a restart interlock/delay configured in the S300 depends on the
integration of the EFI status information from the S300 in the logic of the Flexi Soft
safety controller.
Further topics
•
•
3.2.8.3
Interoperability with sens:Control devices
The safety laser scanner can be connected to the following sens:Control devices and
thereby integrated into the respective bus system.
PRODUCT DESCRIPTION
3
8010948/ZA21/2020-06-18 | SICK
O P E R A T I N G I N S T R U C T I O N S | S300
23