150 mm
150 mm
190 mm
110 mm
1
1
Figure 38: Fitting height
1
Set protective field length
NOTE
You can also mount the device upside down in order to achieve the optimal scan plane.
4.4
Integration in electrical control
4.4.1
Connection diagrams
Important information
WARNING
Ineffectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
Downstream contactors must be positively guided and monitored depending on regula‐
tions applicable at the operation site or required reliability of the safety function.
b
Make sure that downstream contactors are monitored (external device monitoring,
EDM).
4
PROJECT PLANNING
50
O P E R A T I N G I N S T R U C T I O N S | S300
8010948/ZA21/2020-06-18 | SICK
Subject to change without notice