Static 1-of-n sampling
With 1-of-n sampling, you use the single connections of the control input pairs. In this
way, the S300 Advanced provides four input connections.
With 1-of-n sampling, you use the single connections of the control input pairs. In this
way, the S300 Professional provides six input connections.
With 1-of-n sampling, you use the single connections of the control input pairs. In this
way, the S300 Expert provides six input connections.
NOTE
•
Using external inputs (e.g., those of a Flexi Soft safety controller), a maximum of
ten input connections can be used.
•
All connections must be connected.
•
Once connection must be 1.
•
Only one connection is ever allowed to be 1.
Table 25: Truth table for 1-of-n sampling
A1
A2
B1
B2
C1
C2
D1
D2
E1
E2
E.g.
case
1
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
2
0
0
1
0
0
0
0
0
0
0
3
0
0
0
1
0
0
0
0
0
0
4
0
0
0
0
1
0
0
0
0
0
5
0
0
0
0
0
1
0
0
0
0
6
0
0
0
0
0
0
1
0
0
0
7
0
0
0
0
0
0
0
1
0
0
8
0
0
0
0
0
0
0
0
1
0
9
0
0
0
0
0
0
0
0
0
1
10
1
1
0
0
0
0
0
0
0
0
Error
0
0
0
1
1
0
0
0
0
0
Error
0
0
0
0
0
0
0
0
0
0
Error
And all other combinations
Error