8
Commissioning
8.1
Safety
Important information
DANGER
Dangerous state of the machine
b
Make sure that the dangerous state of the machine is and remains switched off
during mounting, electrical installation, and commissioning.
b
Make sure that the outputs of the safe multibeam scanner do not affect the
machine during mounting, electrical installation, and commissioning.
WARNING
Dangerous state of the machine
The machine or the protective measure may not yet behave as you have planned.
When changes are made to the machine, the effectiveness of the protective measure
may be affected unintentionally.
b
Before commissioning the machine, make sure that the machine is first checked
and released by qualified safety personnel.
b
Only operate the machine with a perfectly functioning protective device.
b
Check the effectiveness of the protective measure after each change to the
machine, the integration or the operating and boundary conditions of the safe
multibeam scanner. Perform commissioning again.
8.2
Overview
Prerequisites
•
Project planning has been completed.
•
Mounting is complete.
•
Electrical installation is completed.
•
Configuration is completed.
•
No-one is in the hazardous area during commissioning.
Further topics
•
•
•
"Electrical installation", page 39
•
8.3
Alignment
If the safe multibeam scanner has been mounted on the machine using the optional
alignment bracket, you can align the safe multibeam scanner vertically in both direc‐
tions by up to 10°. For further information, see the separately available mounting
instructions of the alignment bracket.
8.4
Switching on
After the device is switched on, the STATE LED and the OSSD-LED light up briefly and
the safe multibeam scanner initializes itself.
8
COMMISSIONING
60
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 I/O
8025936/2021-01-08 | SICK
Subject to change without notice