0
5
10
15
20
25
30
35
40
45
50
55
100
200
300
400
500
600
700
800
Line rate (kHz)
Number of rows
1
2
3
4
5
6
7
8
Figure 83: The maximum line rate as a function of the number of sensor rows used.
1
Line rate (kHz)
2
Number of rows
3
Ruler3000 with HDR enabled
4
Ruler3000 without HDR enabled
5
Bandwidth limitation for image width 2560, only Range
6
Bandwidth limitation for image width 3072, only Range
7
Bandwidth limitation for image width 2560, Range and Reflectance
8
Bandwidth limitation for image width 3072, Range and Reflectance
13.4
Interfaces
Product
Ruler3020
Ethernet
UDP/IP
1 Gbit/s (data transmission rate)
Configuration software
Stream Setup
Communication interfaces
Gigabit Ethernet/GigE Vision
Operating system
Windows 10
Programming interface
GenAPI, GenTL, proprietary SICK GenIStream
Configurable digital inputs
4 x HTL = 10 V ... 28.8 V
Configurable digital out‐
puts
1 x HTL, 2 x TTL
Encoder interface
RS-422 or 2 x HTL single-ended
External illumination con‐
trol
RS-422 5 V TTL or HTL 24V
13.5
Ambient data
Product
Ruler3020
Shock load
15 g, 3 cycles per axis
Vibration load
5 g, 10 Hz ... 150 Hz
13
TECHNICAL DATA
90
O P E R A T I N G I N S T R U C T I O N S | Ruler3000
8026049//2021-04 | SICK
Subject to change without notice