10
Maintenance
10.1
Maintenance plan
During operation, the device works maintenance-free.
NOTE
No maintenance is required to ensure compliance with the laser class.
NOTE
No maintenance is required to ensure compliance with the LED risk group.
Table 9: Maintenance plan
Maintenance work
Interval
To be carried out
by
Check device and connecting cables
for damage at regular intervals.
Depends on ambient conditions and
climate.
Specialist
Clean housing.
Depends on ambient conditions and
climate.
Specialist
Check the screw connections and
plug connectors.
Depends on the place of use, ambi‐
ent conditions or operating require‐
ments. Recommended: At least every
6 months.
Specialist
Check that all unused connections
are sealed with protective caps.
Depends on ambient conditions and
climate. Recommended: At least
every 6 months.
Specialist
10.2
Cleaning
NOTICE
Equipment damage due to improper cleaning.
Improper cleaning may result in equipment damage.
■
Only use recommended cleaning agents and tools.
■
Never use sharp objects for cleaning.
b
Clean the housing with a soft cloth, dry or dampened with a mild water-diluted
cleaning agent without powder additives.
b
Keep the windows clean to maintain the performance of the device. Regularly
check the windows for contamination such as dust or humidity. If there is contam‐
ination, gently clean the windows with a soft, damp cloth. Use a mild cleaning
agent if needed.
Cleaning procedure:
Operating the product in conjunction with external illumination systems may result in
hazardous radiation exposure. Please note the accompanying production documenta‐
tion.
10
MAINTENANCE
82
O P E R A T I N G I N S T R U C T I O N S | Ruler3000
8026049//2021-04 | SICK