Table 24: TSRDO contents
Entry
Index
Subindex
Description
1
0x6200
1
Device status
2
0x6201
1
Device status inverted
3
0x6200
2
Reserved
4
0x6201
2
Reserved inverted
5
0x6202
1
Protective field status
6
0x6203
1
Protective field status inverted
7
0x6202
2
Reserved
8
0x6203
2
Reserved inverted
Table 25: TSRDO, entry 1 (device status)
Bit
Name
Description
0
0 = OFF
1 = ON
1
Protective field status
Status of the currently active protective field:
0 = Interrupted
1 = Free
2
Operating status
0 = Safety function OFF or error or sleep mode
1 = Safety function ON and no error and not in
sleep mode
3
-
Reserved
4
-
Reserved
5
-
Reserved
6
-
Reserved
7
-
Reserved
Table 26: TRSDO, entry 5 (protective field status)
Bit
Name
Description
0
Status of the protective field in monitoring
case 1:
0 = Interrupted
1 = Free
1
Status of the protective field in monitoring
case 2:
0 = Interrupted
1 = Free
2
Status of the protective field in monitoring
case 3:
0 = Interrupted
1 = Free
3
Status of the protective field in monitoring
case 4:
0 = Interrupted
1 = Free
4
Status of the protective field in monitoring
case 5:
0 = Interrupted
1 = Free
4