Table 39: Read SDO (example)
CAN-ID
DLC
Data
602h
8
40h
03h
10h
01h
00h
00h
00h
00h
The server responds:
Table 40: SDO read conformation (example)
CAN-ID
DLC
Data
582h
8
43h
03h
10h
01h
08h
00h
50h
02h
The response data combine to the 32-bit word 02500008h.
Further topics
•
4.5.2
Factory settings
Table 41: Factory settings of the CANopen parameters
Parameter
Default value
Description
Baud rate
125 kbit/s
Node ID
1
NMT Autostart
False
Heartbeat time
0 ms
Sync Producer
False
Communication Cycle Period
0 µs
Only relevant if the Synchroni‐
zation object (SYNC) producer
function is activated.
Activate PDOs
TPDO1: Active
RPDO, TPDO2 … TPDO9: Inac‐
tive
Available for every PDO
Activate SRDOs
Deactivated
Available for every SRDO
PDO - COB-ID
TPDO1: 0x180 + node ID
TPDO2: 0x280 + node ID
TPDO3: 0x380 + node ID
TPDO4: 0x480 + node ID
TPDO5: 0x680 + node ID
TPDO6: 0x1C0 + node ID
TPDO7: 0x2C0 + node ID
TPDO8: 0x3C0 + node ID
TPDO9: 0x4C0 + node ID
RPDO1: 0x200 + node ID
PDO - Transmission Type
0xFF
Available for every PDO
PDO - Inhibit Time (100 µs)
0
Available for every PDO
PDO - Event Time
TPDO1: 10 ms
RPDO, TPDO1 … TPDO9: 0 ms
Available for every PDO
TSRDO - COB-ID
COB-ID1: 0xFF + 2 x node ID
COB-ID2: 0x100 + 2 x node ID
RSRDO - COB-ID
COB-ID1: 0x111
COB-ID2: 0x112
SRDO - Refresh Time/Safe‐
guard Cycle Time (SCT)
TSRDO: 25 ms
RSRDO: 50 ms
Available for every SRDO
SRDO - SRVT
20 ms
Available for every SRDO
PROJECT PLANNING
4
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
43