The system connection be routed away in different directions.
!
Figure 18: Mounting the safe multibeam scanner
!
Fixing holes
Prerequisites
•
Project planning has been completed.
•
Mount according to project planning.
•
Installation location provides protection against moisture, dirt and damage.
•
Status indicators are easily visible after mounting.
Approach
1.
Screw the safe multibeam scanner to the machine through the two fixing holes.
NOTE
•
Use M5 screws.
•
Minimum depth of thread: 12 mm.
•
Tightening torque: 4.5 Nm … 5.0 Nm.
•
In case of strong vibrations (see data sheet), use screw locking devices to secure
the fixing screws.
Complementary information
You can also mount the safe multibeam scanner using the optionally available align‐
ment bracket. When mounted using the alignment bracket, the device can be rotated
vertically and aligned. For further information, see the separately available mounting
instructions of the alignment bracket.
Further topics
•
•
"Dimensional drawings", page 103
•
5
MOUNTING
60
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK
Subject to change without notice