6
Electrical installation
6.1
Safety
Important information
DANGER
Dangerous state of the machine
b
Make sure that the dangerous state of the machine is and remains switched off
during mounting, electrical installation, and commissioning.
b
Make sure that the outputs of the safe multibeam scanner do not affect the
machine during mounting, electrical installation, and commissioning.
6.2
Connecting
Overview
The device is connected via the M12 plug connector.
Prerequisites
•
Project planning has been completed.
•
Mounting is complete.
•
Electrical installation according to project planning.
•
Electrical installation according to the requirements of
ment into the electrical control", page 30
.
Further topics
•
•
6.2.1
System connection (M12, 5-pin)
Voltage supply and CAN signals
•
Male connector
•
M12
•
5-pin
•
A-coded
2
1
4
3
5
Figure 19: System connection (male connector, M12, 5-pin, A-coded)
Table 45: System connection pin assignment (male connector, M12, 5-pin)
PIN
Designation
Function
1
CAN shield
Shielding
2
+24 V DC
Supply voltage (24 V DC)
3
0 V DC
Supply voltage (0 V DC)
4
CAN HIGH
CAN signal
5
CAN LOW
CAN signal
ELECTRICAL INSTALLATION
6
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
61