Area zoom
Fit to window size
Display live measuring data
Field display
The fields in Safety Designer are drawn in a Cartesian coordinate system. The zero
point is located in the middle of the back of the safe multibeam scanner.
The fields are displayed realistically. Due to the functioning of the safe multibeam
scanner and the division of the detection area into 32 segments, the contour of the
fields may contain steps.
Based on the drawn field, the Safety Designer calculates the distance from the safe
multibeam scanner to the end of the drawn field for all 32 segments. The front screen
of the safe multibeam scanner is the reference point for the calculation. The calculated
distance values can be viewed on the
Report
page.
Safety Designer displays the field types in different colors.
Table 48: Colors of the field types
Red
Yellow
Fields and field sets
You can create up to 8 field sets. You can create one protective field and one warning
field per field set.
If you create a field set with a protective field and a warning field, you should first
create the protective field and then the warning field. The fields are then assigned to
the correct outputs in the monitoring case table.
Table 49: Buttons on the toolbar
Add field to field set
Delete field or field set
To display or edit the protective field or warning field in the
Fields
area, click on the
relevant field in the field set.
Object resolution
First set the object resolution for all fields in the
General field settings
area. If necessary,
you can make changes to each individually at a later date.
Multiple sampling
First set the multiple sampling for all fields in the
General field settings
area. If necessary,
you can make changes to each individually at a later date.
7
CONFIGURATION
74
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK