To avoid mutual interference in all cases, you need to choose a suitable mounting
method.
Suitable mounting methods:
b
Offset mounting so that the scan planes are on different planes
b
Slightly inclined, tilted mounting, so that the scan planes intersect one another
4.3.2
Preventing unprotected areas
Overview
The safe multibeam scanner must be mounted so that people cannot enter unsecured
areas.
Undetected areas
The safe multibeam scanner has a field of view of 150°. Outside of this field of view,
there may be areas which cannot be detected by the safe multibeam scanner.
"
!
Figure 8: Unsecured areas
!
Width of the unsecured area
"
Length of the unsecured area
Remedial measures:
•
Mounting of deflector plates to protect the undetected areas
•
Mounting the safe multibeam scanner in the machine paneling
PROJECT PLANNING