4.5
Integration into the CANopen network
Prerequisites
•
The safe multibeam scanner and the CAN bus must use the same baud rate.
4.5.1
Supported objects and services
The safe multibeam scanner supports the following CANopen object types and serv‐
ices:
•
Process data objects (PDOs)
•
Safety related data objects (SRDOs)
•
Service data objects (SDOs)
•
Emergency
•
NMT
•
SYNC
•
Heartbeat
•
Node guarding
•
LSS slave
•
Store/restore
4.5.1.1
Process data objects (PDOs)
Overview
The safe multibeam scanner supports one Receive PDO (RPDO) and nine Transmit
PDOs (TPDO1 to TPDO9).
Objects 0x1800 to 0x1808 contain the communication parameters. Objects 0x1a00 to
0x1a08 contain the mapping parameters.
NOTE
The mapping parameters cannot be changed.
RPDO
The safe multibeam scanner receives the input signals for monitoring case switching
via the RPDO object.
The RPDO object uses the index 0x6000 and consists of two entries, each 8 bits in size.
Table 6: RPDO contents
Entry
Index
Subindex
Description
1
0x6000
1
Input signals for monitoring case
switching
2
0x6000
2
Reserved
Table 7: RDPO, entry 1 (input signals for monitoring case switching)
Bit
Name
Description
0
Input 0
1
Input 1
2
Input 2
3
Input 3
4
Input 4
5
Input 5
6
Input 6
7
Input 7
4
PROJECT PLANNING
32
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK
Subject to change without notice