Object
Sub
Access Object name
Default value Type
Description
0x09 RO
SignalStrength8
0
UNSIGNED8
0x0a RO
SignalStrength9
0
UNSIGNED8
0x0b RO
SignalStrength10 0
UNSIGNED8
0x0c RO
SignalStrength11 0
UNSIGNED8
0x0d RO
SignalStrength12 0
UNSIGNED8
0x0e RO
SignalStrength13 0
UNSIGNED8
0x0f RO
SignalStrength14 0
UNSIGNED8
0x10 RO
SignalStrength15 0
UNSIGNED8
0x11 RO
SignalStrength16 0
UNSIGNED8
0x12 RO
SignalStrength17 0
UNSIGNED8
0x13 RO
SignalStrength18 0
UNSIGNED8
0x14 RO
SignalStrength19 0
UNSIGNED8
0x15 RO
SignalStrength20 0
UNSIGNED8
0x16 RO
SignalStrength21 0
UNSIGNED8
0x17 RO
SignalStrength22 0
UNSIGNED8
0x18 RO
SignalStrength23 0
UNSIGNED8
0x19 RO
SignalStrength24 0
UNSIGNED8
0x1a RO
SignalStrength25 0
UNSIGNED8
0x1b RO
SignalStrength26 0
UNSIGNED8
0x1c RO
SignalStrength27 0
UNSIGNED8
0x1d RO
SignalStrength28 0
UNSIGNED8
0x1e RO
SignalStrength29 0
UNSIGNED8
0x1f RO
SignalStrength30 0
UNSIGNED8
0x20 RO
SignalStrength31 0
UNSIGNED8
4.6
Testing plan
The manufacturer of the machine and the operating entity must define all required
thorough checks. The definition must be based on the application conditions and the
risk assessment and must be documented in a traceable manner.
The following tests must be planned:
•
Test during commissioning and in certain situations
•
Regular thorough checks
A test object is required for some thorough checks. An optically opaque cylinder with
a black surface can be used as a suitable test object. The diameter must match the
configured resolution.
Further topics
•
4.6.1
Test during commissioning and in certain situations
Minimum requirements
The protective device and its application must be thoroughly checked in the following
situations:
•
Before commissioning
•
After changes to the configuration or the safety function
PROJECT PLANNING
4
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
55