7
Configuration
7.1
Overview
Overview
Before commissioning, you need to configure the safe multibeam scanner according to
the project planning.
Delivery state
The safe multibeam scanner is not configured in the delivery state.
Interfaces and applications for configuration
NOTICE
The computer used for configuration must be protected against unintentional interfer‐
ence or modification (e.g. by anti-virus software and firewall).
The safe multibeam scanner has a USB interface and an NFC interface that you can
use for configuration. You can use the following applications from SICK AG for configu‐
ration:
•
USB connection to a computer: Safety Designer (software for configuring and
diagnosing safety solutions)
•
NFC connection to an NFC-capable mobile device: Safety Assistant (app for trans‐
ferring configurations and diagnosing safety solutions)
The CANopen configuration is independent of a verified configuration. Changes to the
CANopen configuration can also be made via the CAN bus.
You can use Safety Designer to configure the safe multibeam scanner and verify the
configuration.
If you want to configure several devices in the same way or if you want to replace a
device, you can use the Safety Assistant app to read a verified configuration from one
device and transfer it to another device.
The USB connection and the NFC interface may only be used temporarily and only for
configuration and diagnostics.
Configuration settings
You can configure the following settings for the safe multibeam scanner:
•
Object resolution
°
Jointly for all protective and warning fields
°
Individually for individual protective or warning fields
•
Multiple sampling
°
Jointly for all protective and warning fields
°
Individually for individual protective or warning fields
•
Create field sets with one protective and one warning field each
•
Draw protective and warning fields
•
Create monitoring cases
°
Assign field sets
°
Configure sleep mode
•
Adjust the general CAN parameters for the communication of the safe multibeam
scanner within the network
°
Node ID
°
Baud rate
°
NMT Autostart
CONFIGURATION
7
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
63
Subject to change without notice