Heartbeat time
°
SYNC Producer
•
Activate or deactivate SRDOs and PDOs
•
CANopen parameters for activated SRDOs and PDOs (e.g., COB-ID)
Further topics
•
see "Checksum calculation", page 44
7.2
User groups
Overview
The devices contain a hierarchy of user groups that regulate access to the devices.
For certain actions (e.g., transferring a configuration to the device), you are requested
to log on with a specific user group. You can view the diagnostic data of a device with
any user group.
You can manage the user groups using either the Safety Designer or the Safety Assis‐
tant app. Depending on your own user group, you can change the passwords of certain
user groups or enable or disable certain user groups.
Important information
NOTICE
If you leave a computer that is connected to devices unattended, you must log out and
switch to the
Machine operator
user group so that unauthorized persons cannot transfer
configurations to the devices.
User groups
Table 46: User groups
User group
Password
Authorizations in Safety
Designer
Authorizations in the
Safety Assistant app
Machine oper‐
ator
No password required.
Anyone can log on as
a machine operator.
•
May read configuration
from the device.
•
May read configuration
from the device.
Maintenance
personnel
Deactivated ex-works,
i.e. it is not initially
possible to log on as
a maintenance techni‐
cian. The user group
can be activated by
the user group admin‐
istrator and provided
with a password.
•
May read configuration
from the device.
•
Changing own password
allowed.
•
May read configuration
from the device.
•
May transfer verified
configuration to the
device.
•
Change own password
allowed.
Authorized cli‐
ent
Deactivated ex-works,
i.e. it is not initially
possible to log on
as an authorized cus‐
tomer. The user group
can be activated by
the user group admin‐
istrator and provided
with a password.
•
May read configuration
from the device.
•
May transfer verified
and unverified configu‐
ration to the device.
•
May verify configura‐
tion.
•
Change own password
allowed.
•
Changing the password
of the
Maintenance per‐
sonnel
user group is
allowed.
•
May read configuration
from the device.
•
May transfer verified
configuration to the
device.
•
Change own password
allowed.
•
Changing the password
of the
Maintenance per‐
sonnel
user group is
allowed.
7
CONFIGURATION
64
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK
Subject to change without notice