7.4.3
Verifying the configuration in Safety Designer
Overview
By verifying the configuration, you can confirm that the configuration complies with the
planned safety function and fulfills the requirements in the risk assessment.
During verification, Safety Designer reads back the transmitted configuration from the
safe multibeam scanner. It compares the configuration with the configuration saved
in Safety Designer. If both configurations are identical, Safety Designer displays the
verification report. If the user confirms that this is correct, the system is considered to
be verified.
Important information
DANGER
Hazard due to lack of effectiveness of the protective device
Errors can occur when transferring the configuration to the device, e.g. due to environ‐
mental influences or faulty cables. The verification report always contains the exact
settings stored in the device.
b
Check the verification report carefully before confirming.
DANGER
Hazard due to lack of effectiveness of the protective device
The CANopen configuration is not part of the verified configuration.
b
Check the CANopen configuration separately.
Prerequisites
•
The configuration corresponds to the planned safety function and meets the
requirements of the risk assessment.
Approach
1.
Connect the device to the computer via USB.
2.
Open the connected device in the device window.
3.
Click on
Identify the device
on the toolbar to ensure that the desired device is
connected.
✓
The STATE LED of the connected device flashes red and green alternately.
4.
In the main navigation pane, click on
Configuration
.
✓
The
Configuration
menu opens. The different pages within the configuration are
displayed in the
Navigation
area.
5.
Click on
Transfer
.
✓
The
Transfer
page opens. On this page, you will find the device being configured in
Safety Designer on the left, and the connected physical device on the right. The
checksums of the two devices indicate whether the configurations differ.
6.
If the checksums are different, click on
Transfer to device
.
✓
The transfer process is displayed in Safety Designer. Safety Designer will notify you
as soon as the transfer process is complete.
✓
The Safety Designer indicates that the configuration is identical, but has not yet
been verified.
✓
The
Verify
button appears on the toolbar.
7.
On the toolbar, click on
Verify
.
✓
Safety Designer displays the verification report.
8.
Thoroughly review the verification report.
CONFIGURATION
7
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
69