9
Technical data
9.1
Technical data
Table 3: Features
Features
Housing material
Fiberglass-reinforced thermoplastic
Enclosure rating (IEC 60529)
IP 67
Mechanical service life
2 × 10
6
Switching operations
B
10d
(EN ISO 13849) at DC-13 100 mA / 24 V
2 × 10
6
Switching operation with small load
Type
Type 2 (EN ISO 14119)
Coding level of the actuator
Low coding level (EN ISO 14119)
Ambient operating temperature
–20 °C … +55 °C
Connection type
M 20
Max. actuation speed
20 m × min
–1
Max. actuation frequency
1,200 × min
–1
Pollution degree
(external, according to EN 60947)
3 × (industry)
Max. actuating force at 20 °C
35 N
Max. force against which unlocking is possible 20 N
Max. retaining force, unlocked
30 N
Locking force F
max
i15-*M (metal actuating head)
i15-*M (metal actuating head) with angled
actuator
i15-*P (metal actuating head)
2,000 N
1,500 N
1,000 N
Locking force F
Zh
according to (EN ISO 14119)
(F
Zh
= F
max
/1.3)
i15-*M (metal actuating head)
i15-*P (metal actuating head)
1,500 N
700 N
Minimum door radii
Table 4: Electrical data
Electrical data
Thermal current l
th
4 A
Switching principle
Slow action switching element
Wire cross-section, (rigid/flexible)
0.34 mm²... 1.5 mm²
Rated insulation voltage U
i
250 V
Rated impulse withstand voltage U
imp
2.5 kV
Utilization category (IEC 60947-5-1)
AC-15: 230 V, 4 A; DC-13: 24 V, 4 A
Min. switching voltage
1)
12 V
Min. switching current at 24 V DC
1 mA
Conditional rated short-circuit current
100 A
Short-circuit protection (control fuse) (IEC
60269)
4 A gG
Solenoid supply voltage (+10% … –15%)
AC/DC 24 V
Max. solenoid power
6 W
9
TECHNICAL DATA
20
O P E R A T I N G I N S T R U C T I O N S | i15 Lock
8020548/1FVF/2022-04-27 | SICK
Subject to change without notice