IO-Link Index
Object name
Description
2
Standard Command 208 / Blank all
currently blocked beams
Blanks all currently blocked
beams. Blanked beams are no
longer taken into account in
object detection.
2
Standard Command 209 / Blank all
currently made beams
Blanks all currently free beams.
Blanked beams are no longer
taken into account in object
detection.
66
Performance options
Cross beam
can lead to an
improvement in resolution. The
height of the adjustable cross‐
over depends on the SLG-2 var‐
iant used.
69
Alignment aid enable
Activation or deactivation of the
alignment aid. When the align‐
ment aid is active, no process
data or detection information is
transmitted.
71
Auto teach-in
When activated: After connect‐
ing the voltage supply, a teach-
in is performed automatically.
72
Beam mask
Individual blanking of individual
beams. The blanked beams are
not considered in the evalua‐
tion.
74
Beam numeration
Command changes the beam
order:
true = 1. Beam at front side
false = 1. Beam at male connec‐
tor side
109
Alignment aid
Displays the signal strength
of the three beams relevant
for alignment, each in a subin‐
dex. Values from 0-100 (percen‐
tages). Value 255 is displayed
for a
Hardware error
.
NOTE
Detailed information on the subindices and access can be found in the IO-Link supple‐
ment (8389226).
7.6
Zones
/
Q
ints
In the
Zones/Q
int
tab, it is possible to define several ranges or zones.
A maximum of 4 zones can be defined.
The zones are displayed in tabular form on the right side. You can parameterize the
zones there. The zones are also shown in the system schematic (center).
Specific measurement functions can be defined within each zone. The result is passed
on to an internal output state (Q
int
), which in turn can be used for further functions
(
Smart Task
). The Q
int
status and measurement results of a zone can also be output via
the serial interface (
).
7
OPERATION
30
O P E R A T I N G I N S T R U C T I O N S | SLG-2
8026014/2021-06-10 | SICK
Subject to change without notice