Figure 35: System status in SOPAS
The system status contains device-specific diagnostic information and has a length of
one byte. Each bit represents different diagnostic information.
Table 16: IO-Link index of device-specific diagnostic information
IO-Link Index
Object name
Description
100
System status
Device-specific diagnostic infor‐
mation transmittable via the
process data
Table 17: Bits of the device-specific diagnostic information
Bit number
System status
Type
Bit 0
Pin short circuit error
Error
Bit 1
Invalid process data
Error
Bit 2
Temperature or operating
hours alarm
Warning
Bit 3
Busy
Note
Bit 4
Quality of run alarm
Warning
Bit 5
Hardware error
Error
Bit 6
Teach-in error
Error
(a warning in IO-Link
Events)
Bit 7
Sync error
Error
(a warning in IO-Link
Events)
The system status can be transmitted cyclically via the process data. Configuration of
the process data is described in
.
In addition, the
System status
information can also be transmitted as a 1-bit value “OR”
function via pin 2 / MF. A selection of diagnostic information relevant for the application
is possible here (
see "Diagnostic settings", page 39
8.3
Diagnostic information via the display LEDs