Timer function
Deactivated
Switch-on delay
Switch-off delay
Switch-on and -off delay
Pulse (One Shot)
Inverter
✓
Switching signal Q
L1
Switching output
Switching signal Q
L2
Switching output
11.1
Resolution
To determine the resolution, 3 essential parameters have to be distinguished:
MDO: Minimum detectable object = minimum object size
MOL: Minimum object length
MOW: Minimum object width (only relevant in cross-beam mode)
The minimum object size differs between parallel-beam mode and cross-beam mode.
Description,
.
11.1.1
Minimum object size (MDO)
Parallel operation
Table 28: MDO in parallel-beam mode
Beam separation
Minimum object size (MDO)
10 mm
15 mm
25 mm
30 mm
50 mm
55 mm
Cross-beam mode
A description of cross-beam mode can be found in
In cross-beam mode, the MDO depends on the beam separation, the cross-beam
option and the object position between the sender and receiver. The following graphic
serves for a better understanding:
11
TECHNICAL DATA
54
O P E R A T I N G I N S T R U C T I O N S | SLG-2
8026014/2021-06-10 | SICK
Subject to change without notice