7.5
General settings
Figure 17: SOPAS - General settings tab
The following settings are possible in the
General settings
tab:
•
Switching threshold setting: The SLG-2 receiver is set to an optimum switching
threshold via the
Teach-in
to ensure reliable detection with sufficiently high resist‐
ance to contamination or other influences.
•
Alignment aid
: The
Alignment aid
function helps to optimally align the light grids (
"Alignment aid via SOPAS ET", page 28
)
•
Auto teach-in
: A teach-in is performed automatically after connection to the voltage
supply (
•
Beam blanking: The
Beam blanking
can be used to blank beams that are not to be
taken into account in the evaluation. This is useful if, for example, a static object is
permanently blocking the light path. The following options are available:
°
Beam blanking
by entering the beam number of the beam to be blanked
°
Beam blanking
by right-clicking on the beam that is to be blanked
°
Blank currently made beams
blanks all beams that are not blocked by an object
during execution.
°
Blank currently blocked beams
blanks all beams that are blocked by an object
during execution.
°
Reset blanking
: Switches all beams back to active
•
Cross beam
: The
Cross beam
function can be used to increase the resolution in cer‐
tain ranges. For this purpose, a 3-fold and, for certain variants, also a 5-fold, 7-fold
or 9-fold crossover is available. The amount of maximum possible crossover also
depends on the distance between the sender and receiver. Detailed information
on the cross-beam function can be found in
.
•
Beam numeration
: The order of beam numbering can be changed. This also outputs
the
Beam status
in a different order.
•
Beam number 1 is at connector side
: Beam numbering starts at the male connector
side of the housing.
•
Beam number 1 is at head side
: Beam numbering starts at the front of the housing.
7.5.1
Alignment aid via SOPAS ET
With the
Alignment aid
, an alignment aid is available via IO-Link for precise alignment of
the SLG-2 light grid (
see "General settings via IO-Link", page 29
). The values can be
displayed graphically via SOPAS ET.
7
OPERATION
28
O P E R A T I N G I N S T R U C T I O N S | SLG-2
8026014/2021-06-10 | SICK
Subject to change without notice