Operating Instructions
Chapter
3
CLV65x Bar Code Scanner
Quick-Start
8011980/0000/2009-04-21
©
SICK AG · Division Auto Ident · Germany · All rights reserved
21
If the SOPAS-ET configuration software runs in
Single Device Mode
, a simplified register tab
is shown:
Fig. 3-2:
Quickstart register tab in Single Device Mode
Performing the reading
Important
The autofocus function is deactivated by default and the focus position is 500 mm (19.7 in).
Automatic focus adjustment is described in
chapter 4.6.3 Autofocus function, page 31
.
1. Ensure that the relevant code types are activated on the register tab.
2. Carry out a test reading with a test bar code.
To achieve this, hold an object with a bar code in front of the bar code scanner's reading
window and trigger the reading by clicking S
TART
. If necessary, observe the bar code
scanner's depth of fields ranges depending on resolution (see
During reading operation and with default settings, the line scanner with oscillating mir-
ror deflects the scanning line by the central position with a frequency of 1 Hz and at a
max. angle of ± 20°.
The reading result is displayed in the B
ARCODE
C
ONTENT
display field.
The code reading reliability is specified in the relevant display field.
Optimise the reading conditions
If no reading result is displayed or if you wish to increase the code reading reliability, the
reading can be repeated by taking the following measures:
Install the bar code scanner in such a way that the bar code scanner's light meets the
idle object (code) at a 15° angle (skew).
Correct or optimise the parameter values where necessary via the SOPAS-ET configura-
tion software.