Operating Instructions
Chapter
4
CLV65x Bar Code Scanner
Product description
8011980/0000/2009-04-21
©
SICK AG · Division Auto Ident · Germany · All rights reserved
37
4.6.13
Digital inputs
The external sensor for the object triggering (photoelectric reflex switch) and the incremen-
tal encoder, e.g., can be connected to the digital switching inputs.
Important
The connection "Sensor 2" is only available in the standard version of the bar code scanner.
For the Ethernet version of the bar code scanner, this input is only available with the con-
nection module CDB620/CDM420 in combination with the parameter memory module
CMC600.
4.6.14
Digital outputs
With certain events in the reading process (e.g. for unsuccessful decoding "No Read"), two
independent switch signals can be generated at both digital outputs and can be used, e.g.,
to display the event status.
Important
The switching outputs "Result 1" and "Result 2" are only available in the standard version of
the bar code scanner. For the Ethernet version of the bar code scanner, the two outputs are
only available with the connection module CDB620/CDM420 in combination with the para-
meter memory module CMC600.
Note
The digital inputs can be configured using the SOPAS-ET configuration software:
P
ROJECT
T
REE
, CLV65
X
, P
ARAMETER
, N
ETWORK
/ I
NTERFACE
/ IO
S
, D
IGITAL
I
NPUTS
Note
The digital outputs can be configured using the SOPAS-ET configuration software:
P
ROJECT
T
REE
, CLV65
X
, P
ARAMETER
, N
ETWORK
/ I
NTERFACE
/ IO
S
, D
IGITAL
O
UTPUTS