Chapter
4
Operating Instructions
CLV65x Bar Code Scanner
42
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011980/0000/2009-04-21
Product description
4.7.4
Parameter set on the Micro SD memory card (optional)
The bar code scanner stores configured parameter values in the internal PROM as well as
on the Micro SD memory card (cloning), provided that this card has been inserted into the
bar code scanner. If the bar code scanner needs to be replaced, the memory card enables
easy and quick transfer of the parameter set to the new device (see
Important
In order to avoid data loss, the Micro SD memory card may only be removed and inserted
into the new device after the respective bar code scanner has been switched off and de-
energized. When inserting the memory card, make sure that the contacts point backwards
and upwards (towards the inscription "mircoSD" on the box slot).
The memory card is located behind a black rubber cover attached to the bar code scanner.
Fig. 4-8:
Micro SD memory card for storing the parameter set
Important
To maintain the enclosure rating IP 65, the black rubber cover has to be closed and lie flush
against the device.
As an alternative to the Micro SD memory card in the bar code scanner, the external, optio-
nal parameter memory module CMC600 in connection module CDB620/CDM420 may also
be used for storing the parameter set. If both the Micro SD memory card and the parameter
memory module CMC600 are available, the bar code scanner will load the parameter set
from the CMC600.