7.3.2
Starting the SOPAS-ET configuration software and calling the scan assistant
1. Switch the power supply to the bar code scanner on.
The bar code scanner performs a self-test and is initialised.
2. Switch on the PC and start the SOPAS-ET configuration software.
The SOPAS-ET configuration software opens the program window with an English pro-
gram interface by default.
3. In order to change the language setting, click on C
ANCEL
and change the language of
the program interface to e. g. G
ERMAN
/D
EUTSCH
via the menu T
OOLS
/O
PTIONS
.
4. Once the language setting has been changed, shut down the SOPAS-ET configuration
software and restart it.
5. In the dialog window, select the option C
REATE
A
NEW
P
ROJECT
and click on OK to confirm
it.
6. Click on the C
ONFIGURATION
button in the main window under S
CAN
A
SSISTANT
.
The S
CAN
A
SSISTANT
dialog window appears.
7.3.3
Configuring the Ethernet connection
TIP
To establish a connection quickly and easily via Ethernet, the SOPAS-ET configuration soft-
ware has a C
ONNECTION
W
IZARD
in the T
OOLS
menu.
Manual configuration:
1. In the dialog window S
CAN
A
SSITANT
under I
NTERNET
P
ROTOCOL
/I
NTERNET
P
ROTOCOL
(IP),
check the check box for E
NABLE
IP C
OMMUNICATION
.
2. Click on the A
DD
... button.
3. Enter the IP address of the bar code scanner and confirm it by pressing OK in the dialog
window.
The dialog window closes. A new entry appears in the IP A
DDRESS
CONFIGURATION
list.
4. Click on OK to confirm settings.
The dialog window A
DVANCED
SCAN
SETTINGS
closes.
7.3.4
Configuring the serial connection
1. In the dialog window S
CAN
A
SSISTANT
under S
ERIAL
P
ORT
/S
TANDARD
P
ROTOCOL
, check the
check box for E
NABLE
S
ERIAL
C
OMMUNICATION
.
2. Click on the A
DVANCED
... button.
3. Under S
ELECT
B
AUDRATE
(
S
) deactivate all the baud rates except 57.6
K
B
D
.
4. Select the following P
ORT
SETTINGS
: 8 data bits, no parity, 1 stop bit.
5. Click on OK to confirm settings.
The dialog window A
DVANCED
SCAN
SETTINGS
closes.
7.3.5
Carrying out a scan
1. In the dialog window S
CAN
A
SSISTANT
click on the N
ETWORK
S
CAN
button.
2. Select the listed devices (CLV65x) and confirm via A
DD
DEVICE
.
Connected devices are searched for via the connection. The SOPAS-ET configuration
software inserts the found devices in the project tree and uploads the current parame-
ter set (S
YNC
C
HECK
).
3. For configuration of the devices see
chapter 7.4.2 Configuring the bar code scanner,
.