Operating Instructions
Chapter
3
AFS60/AFM60 EtherNet/IP
37
Product description
3.5.12
Resetting the configuration
There are two possibilities to reset the configuration.
You can reset the configuration of the AFS60/AFM60 EtherNet/IP to the factory settings.
Set the IP address to xxx.xxx.xxx.888 (see section 3.5.1 “IP address” on page 34).
The next time the encoder is started up, all parameters are reset to the factory settings.
You can set the configuration of the AFS60/AFM60 EtherNet/IP to the settings last saved
in the non-volatile memory.
Set the IP address to xxx.xxx.xxx.000.
The next time the encoder is started up, all connection parameters (such as IP address,
DHCP etc.) are set to the settings last saved in the non-volatile memory.
3.6
Controls and status indicators
The AFS60/AFM60 EtherNet/IP Absolute Encoder has five LEDs.
Three of the LEDs indicate the operating status (Net, Mod and Encoder), two the status of
the Ethernet interface (Link 1 and Link 2).
The LEDs are multi-colored. Tab. 23 on page 65 and Tab. 24 on page 66 show the
meaning of the signals.
There are the following controls under the screw cover:
decade switches for the address setting
preset push-button
Fig. 13: Position of the LEDs,
the decade switches and the
preset push-button
Link 1
Encoder
Link 2
Mod
Net
Screw cover
8018909/1EH9/2021-12-16
Subject to change without notice
© SICK AG• Germany • All rights reserved