Operating Instructions
Chapter
4
AFS60/AFM60 EtherNet/IP
39
Commissioning
4.1.1
Connections of the AFS60/AFM60 EtherNet/IP
The connections of the AFS60/AFM60 EtherNet/IP are on the back.
Ethernet M12 × 4, socket
Voltage supply, M12 × 4, plug
Ethernet M12 × 4, socket
Two Ethernet connections are used if the AFS60/AFM60 EtherNet/IP is integrated in a
DLR or a line topology (see Fig. 3 on page 13).
Pin
Signal
Core color
Function
1
V
S
Brown
Supply voltage 10 … 30 V DC
2
–
White
Do not use
3
GND
Blue
0 V DC (Ground)
4
–
Black
Do not use
Pin 2 and 4 are
not allowed to be assigned
, otherwise irreparable damage could be
caused to the AFS60/AFM60 EtherNet/IP.
Pin
Signal
Core color
7)
Function
1
TxD+
White/orange
Ethernet
2
RxD+
White/gray
Ethernet
3
TxD–
Orange
Ethernet
4
RxD–
Green
Ethernet
Connect the shield to the encoder housing!
Pay attention to the maximum cable lengths.
Mount all cables with strain relief.
7)
On the usage of pre-wired cables.
Fig. 14: Position of the
connections of the
AFS60/AFM60 EtherNet/IP
Fig. 15: Connections of the
AFS60/AFM60 EtherNet/IP
Note
Tab. 21: Pin assignment for
the connection of the voltage
supply
Note
Tab. 22: Pin assignment for
the Ethernet connection
Notes
Voltage supply
Ethernet
Ethernet
8018909/1EH9/2021-12-16
Subject to change without notice